Glossary

A

Aeroderivative gas turbine
An aeroderivative gas turbine is an industrial gas turbine derived from an aircraft engine: a light gas generator with a high pressure ratio and a free power turbine. It starts in minutes, has a high simple-cycle efficiency, allows modular replacement of the gas generator and copes well with variable loads; it is inferior to heavy-duty machines in unit size and hot-section life. Read more
Air-insulated switchgear (AIS)
AIS is air-insulated switchgear: circuit breakers, disconnectors, current and voltage transformers, surge arresters and busbars are installed outdoors on gantries and support structures. The insulating medium is air, so the phase clearances are large and the condition of the apparatus depends on the climate and pollution. Read more
Anti-surge control
Anti-surge control is a control loop of a centrifugal or axial compressor that, from the measured flow, pressures and speed, calculates the position of the operating point relative to the surge line and opens the recycle valve before the compressor goes into surge. It is implemented within the unit control system or as a separate controller. Read more
API standards for compressors and turbines
API standards are the American Petroleum Institute’s requirements for the design, manufacture and testing of equipment for the oil, chemical and gas industries. API 617 covers centrifugal and axial compressors, 618 reciprocating, 619 rotary screw, 672 packaged integrally geared air compressors, 673 centrifugal fans, and 611 and 612 general- and special-purpose steam turbines. Read more
Automatic control system (unit control)
An automatic control system (SAU in Russian) is the unit control system: a controller with application software, cabinets, sensors and actuators that run a gas or steam turbine or a compressor through all modes — start, loading, regulation, shutdown — and protect the machine by speed, vibration, temperatures and pressures. Unlike the plant-wide process control system it works at the level of one unit. Read more

B

Back-pressure turbine
A back-pressure turbine is a steam turbine that exhausts steam above atmospheric pressure, 0.25–4.0 MPa (up to 6.5 MPa for drive machines), into a process network or district heating. The steam does work in the turbine and is then used by consumers, so the overall fuel utilisation reaches 80–90 %. There is no condenser; the turbine output depends on the consumers’ steam demand. Read more
Blower
A blower is a centrifugal or axial machine for delivering air and industrial gases with a small pressure rise: a pressure ratio of up to 1.7, whereas compressors have 2 and above. Flow up to 300,000 Nm³/h, drive power up to 5 MW; built to API 673 for the oil, chemical and gas industries. Read more
Boil-off gas (BOG)
Boil-off gas is the part of liquefied natural gas that evaporates in tanks, pipelines and tankers because of heat ingress from outside: usually 0.05–0.1 % of the storage volume per day. It cannot be vented to the atmosphere, so boil-off gas is compressed and returned to the liquefaction process, sent to the fuel gas system or re-liquefied. Read more
Breaking current
The breaking current is the highest short-circuit current a circuit breaker can interrupt at its rated voltage without damage. It is stated as the r.m.s. value of the periodic component in kiloamperes: 40, 50 or 63 kA for 110–500 kV apparatus. It should not be confused with the rated current — the current the breaker carries continuously in normal operation. Read more

C

Centrifugal compressor
A centrifugal compressor is a dynamic machine in which gas is accelerated by an impeller and then decelerated in a diffuser, converting velocity into pressure. Several stages in one casing give a pressure ratio of up to 25 and a discharge pressure of up to 15 MPa at flows up to 300,000 Nm³/h; drive power up to 30 MW from a steam turbine, gas turbine or electric motor. Built to API 617. Read more
Cogeneration (CHP)
Cogeneration is the combined production of electricity and heat in one plant: the heat of the exhaust gases and the cooling systems of the engine or turbine, which would otherwise be lost, heats water or produces steam. A CHP plant (mini-CHP) is a captive generation complex based on gas engine gensets, microturbines or gas turbines; the overall fuel utilisation reaches 85–90 %. Read more
Combined-cycle plant (CCGT)
A combined-cycle plant is a gas turbine, a heat recovery steam generator and a steam turbine working in one scheme. The heat of the gas turbine exhaust raises steam for the steam turbine, so the same fuel yields 40–50 % more electricity than in simple cycle; the overall electrical efficiency reaches 55–60 %. Read more
Commissioning
Commissioning is the set of checks, adjustments and tests of equipment and control systems after erection and before hand-over to operation. It includes individual tests of components, checks of protection and interlocks, the first start, tuning of operating modes and integrated load trials with hand-over of the equipment to operation. Read more
Compressor surge
Surge is an unstable operating mode of a centrifugal or axial compressor in which the flow and pressure oscillate with a large amplitude and the gas periodically moves backwards through the flow path. It occurs when the flow falls below the stable operating limit; it is dangerous for the flow path, seals and bearings and is prevented by anti-surge control. Read more
Condensing turbine
A condensing turbine is a steam turbine in which the steam expands to below atmospheric pressure and enters a condenser: exhaust 0.005–0.3 MPa abs. The deeper the vacuum, the more work is obtained from each tonne of steam, so condensing machines give the most electricity, but all the exhaust heat is rejected to cooling water. Read more
Control system migration
Control system migration is the step-by-step replacement of the hardware and software platform of an operating control system with another platform while keeping the protection and control algorithms, sensors and actuators. It is applied when the old platform is no longer supported or does not meet requirements: for example, transferring Siemens Energy SPPA-T3000 and SIMATIC PCS 7 systems to the Russian Ezan platform. Read more
Critical information infrastructure (CII)
Critical information infrastructure is the information systems, networks and process control systems of organisations in the sectors listed in Federal Law No. 187-FZ — energy, fuel and energy complex, transport, communications, chemicals, metallurgy and others. A CII subject must categorise its objects, submit the data to FSTEC of Russia and protect the significant objects. Read more
Current transformer
A current transformer is an instrument transformer that converts the current of the power circuit into a proportional secondary current, usually 1 or 5 A, for meters, instruments and protection relays. The primary winding is connected in series with the circuit; in dead-tank breakers and GIS it is built in as a ring core on the bushing or inside the enclosure. Read more

D

Data sheet (questionnaire)
A data sheet is a form in which the customer states the input data for equipment selection: the process medium and its composition, flow, inlet and outlet pressures and temperatures, operating modes, site conditions, requirements for the driver, standards and scope of supply. From the completed data sheet the supplier sizes and selects the machine and prepares a technical and commercial proposal. Read more
Dead-tank circuit breaker
A dead-tank circuit breaker is a high-voltage SF6 circuit breaker whose interrupter is housed in an earthed metal tank filled with SF6 gas; the live parts are brought out through bushings that carry built-in current transformers. Cold-climate versions operate down to −60 °C. Read more
Diaphragm compressor
A diaphragm compressor is a positive-displacement machine in which the gas is compressed by a metal diaphragm flexed by a hydraulic drive: the gas is separated from the oil and does not contact the atmosphere, so compression is free of contamination and leakage. Discharge pressure up to 45 MPa at flows up to 1,000 Nm³/h and power up to 200 kW — for pure, hazardous, rare and corrosive gases. Read more
Digital twin
A digital twin is a mathematical model of a turbine, compressor or boiler that reproduces their characteristics, dynamics and limits from manufacturer and operating data. The control system is connected to the model on a bench to debug the algorithms before going to site, and the model serves as a simulator for training operators in starts, shutdowns and emergencies without risk to the equipment. Read more
DLE (dry low emissions)
DLE (dry low emissions) is “dry” low-emission combustion in a gas turbine: the fuel is premixed with excess air and burns as a lean mixture at a reduced flame temperature, without water or steam injection. Nitrogen oxide emissions drop to 15–25 ppm at 15 % O2 while CO stays low. Read more
Dry gas seals
Dry gas seals are non-contacting mechanical face seals for the shaft of a centrifugal compressor in which the gap between the rotating and stationary rings is maintained by a gas film a few micrometres thick. They replace oil seals: they need no seal oil system, consume almost no power and keep oil out of the process gas. Read more

E

Efficiency of a power unit
The efficiency of a power unit is the ratio of useful energy to the energy of the fuel burnt, based on its lower heating value. Electrical efficiency counts only electricity: 32–40 % for gas turbines, over 41 % for gas engine gensets, 55–60 % for combined-cycle plants. Overall efficiency in cogeneration adds the useful heat and reaches 85–90 %. Read more

F

Fault-tolerant cluster
A fault-tolerant cluster is two or more servers combined so that, if one of them fails, the protected virtual machines and applications continue running on the standby server without data loss and with minimal interruption. The Russian HyperSphere software based on KVM virtualisation is installed on two servers and moves virtual machines to the standby node in real time, replacing VMware vSphere and Stratus everRun. Read more

G

Gas engine genset
A gas engine genset is a gas-fuelled reciprocating internal combustion engine with a generator on the same shaft plus cooling, lubrication and control systems. It produces electricity with an electrical efficiency of more than 41 % and, with recovery of the cooling and exhaust heat, up to 87 % overall. Read more
Gas turbine inspection
A gas turbine inspection is a scheduled examination of the machine by operating hours or after an event: a borescope inspection without disassembly, a combustion inspection, a hot gas path inspection with replacement of worn parts, and a major inspection with full disassembly. The result is a report on the condition, the scope of the coming repair and the need for spare parts. Read more
Gas turbine unit (GTU)
A gas turbine unit is an axial compressor, a combustor and a turbine on a common shaft together with a generator or a driven machine. The compressor compresses air, fuel is added in the combustor, the hot gases expand in the turbine and turn the shaft. It is used for power generation and for the mechanical drive of compressors and pumps. Read more
Gas-insulated switchgear (GIS)
GIS is gas-insulated switchgear: circuit breakers, disconnectors, earthing switches, instrument transformers and busbars are housed in sealed earthed enclosures filled with SF6 gas. It takes 25–30 times less space than air-insulated switchgear, is independent of weather and pollution and lasts more than 50 years. Read more

H

Hardware and software suite (PTK)
A hardware and software suite (PTK in Russian) is the control system platform: controllers, I/O modules, network equipment, servers, workstations and system software on which the plant’s application algorithms are developed and executed. A PLC — programmable logic controller — is the real-time computing core of the suite. Read more
High-voltage test laboratory
A test laboratory is a unit with certified personnel and test equipment registered with Rostechnadzor that performs acceptance and in-service tests and measurements in electrical installations. A mobile high-voltage test laboratory travels to the substation with resonant test systems and tests equipment up to 750 kV on the erection site. Read more
High-voltage withstand test
A high-voltage withstand test checks the insulation of electrical equipment with a voltage above the operating value for a specified time: the insulation must withstand it without breakdown or flashover. For GIS and breakers after erection an AC voltage is applied, usually 80 % of the factory test value, with simultaneous partial discharge measurement. Read more

I

Industrial cybersecurity (OT security)
Industrial cybersecurity is the protection of process control systems from cyber attacks, errors and unauthorised access: security assessment, segmentation of the control network, firewalls, remote access control, security tools compatible with the control platform. Requirements are set by FSTEC of Russia and Federal Law 187-FZ for critical infrastructure; the work is carried out under a licence for technical protection of confidential information. Read more
Installation supervision
Installation supervision is technical direction of equipment erection by a representative of the manufacturer or a specialised service company. The supervising engineer does not carry out the erection but checks that the erection contractor’s work conforms to the documentation, accepts it stage by stage and takes part in the first start-up. Read more
Integrally geared compressor
An integrally geared compressor is a centrifugal compressor with a built-in gearbox: several high-speed pinion shafts with overhung impellers are arranged around a central bull gear, and each stage runs at its own optimum speed. Intercooling between stages reduces the work of compression; pressure ratio up to 35, discharge pressure up to 10 MPa, flow up to 160,000 m³/h. Read more

L

Live-tank circuit breaker
A live-tank circuit breaker is a high-voltage SF6 circuit breaker whose interrupter sits on a support insulating column at line potential. The interrupter and the column are filled with SF6 and form a single gas volume; the operating mechanism is at the base of the column. It is lighter and cheaper than a dead-tank breaker but has no built-in current transformers. Read more
LNG — liquefied natural gas
LNG is liquefied natural gas: methane cooled to −162 °C at near-atmospheric pressure; as a liquid it occupies 600 times less volume, which allows it to be shipped by tanker. An LNG plant comprises feed gas treatment and drying, refrigerant and feed gas compressors, a captive power plant on gas turbines, storage tanks and boil-off gas compressors. Read more

M

Maintenance and overhaul
Maintenance and overhaul is the system of work that keeps equipment in sound condition throughout its life. Maintenance is routine operations without disassembly; a medium overhaul is partial disassembly with replacement of worn components; a major overhaul is full disassembly with restoration of the service life. Intervals are set by operating hours or by condition. Read more
Mechanical drive
Mechanical drive is the use of a steam or gas turbine to turn a working machine directly, without a generator and an electric motor: a compressor, a pump, a fan, an induced-draught fan. A drive turbine varies its speed with the load and so controls the machine’s output without throttling; the steam drive turbines on this site are rated 8 kW – 50 MW. Read more
Microturbine
A microturbine is a small gas turbine unit of 110 to 1,966 kW with a high-speed generator on the same shaft as the compressor and turbine. It runs on natural and associated gas, biogas and industrial waste gases and supplies electricity and heat for distributed generation; NOx emissions no more than 25 ppm, noise no more than 85 dB(A). Read more

P

Paper machine
A paper (or board) machine is a unit up to 200 metres long that forms, dewaters, presses, dries and reels a web of paper or board from a water suspension of fibre. Dozens of sections are driven by a sectional multi-motor drive with precise speed synchronisation; the control system holds web tension, moisture and basis weight. Read more
Partial discharge
Partial discharges are local electrical discharges in insulation that bridge only part of the gap between the electrodes: in a gas void, at a sharp edge, near a particle or a crack. By themselves they do not cause breakdown, but they gradually destroy the insulation, so their level is an indicator of the condition of the equipment. Read more
Process control system (ASU TP)
A process control system (ASU TP in Russian) consists of sensors and actuators, controllers, servers and operator workstations that together measure process values, control the equipment and protect it. At a power facility it ties the control systems of turbines, compressors, boilers and the electrical part into one loop with the operator in it. Read more

R

Rated (highest) voltage
The rated (highest) voltage is the upper limit of voltage at which apparatus operates continuously. For a 110 kV network it is 145 kV to IEC (126 kV to GOST), for 220 kV — 245 kV (252 kV), for 330 kV — 363 kV, for 500 kV — 550 kV (525 kV). This is why a circuit breaker or GIS bay “for 145 kV” is intended for a 110 kV class network. Read more
Reciprocating compressor
A reciprocating compressor is a positive-displacement machine in which gas is compressed by a piston in a cylinder and discharged through valves. It gives the highest pressure among industrial compressors — up to 50 MPa — at moderate flows up to 115,000 m³/h and drive power up to 10 MW; 2 to 10 cylinders with intercooling. Built to API 618 for the oil, chemical and gas industries. Read more
Resident engineer
A resident engineer is a service company specialist permanently based at the customer’s site who supports the operation of turbines and compressors: monitors the condition of the machines, takes part in starts and shutdowns, plans maintenance and spare parts and is the first to respond to abnormal situations. Works on a rotation basis, including at remote sites. Read more
Resonant test system
A resonant test is an AC high-voltage test in which the inductance of the test set and the capacitance of the test object form an oscillating circuit. At the resonant frequency the circuit itself generates the high voltage and the supply only covers the losses — tens of times less power than a test transformer needs. This is how GIS and cables are tested up to 750 kV on site. Read more
Rotor
The rotor is the rotating part of a turbine or compressor: a shaft with shrunk-on or integrally forged impellers, discs and blades, supported by bearings. Its condition determines the vibration, clearances and life of the whole machine; the rotor is balanced, its critical speeds and axial position are monitored, and during repair it is restored or replaced by an exchange rotor. Read more

S

SCADA
SCADA (supervisory control and data acquisition) is the operator-level software of a process control system: data collection from controllers, display of the process on mimic diagrams, trends, event and alarm logs, historian, remote control and reports. HMI — the human-machine interface — is part of SCADA or a local operator panel at the unit. Read more
Screw compressor
A screw compressor is a rotary positive-displacement machine: two helical rotors with meshing profiles carry the gas along the axis, reducing the volume of the cavities and raising the pressure without valves or reciprocating parts. Oil-free (dry) and oil-injected designs; discharge pressure up to 1.3 MPa with atmospheric suction, flow up to 1,070 m³/min, power up to 1.8 MW. Built to API 619. Read more
Self-regulatory organisation (SRO)
An SRO is a self-regulatory organisation in construction: an association of design or construction companies whose membership grants the right to prepare design documentation and to carry out construction, reconstruction and major repairs of capital construction facilities. The SRO verifies the qualifications of its members and is liable for their obligations through compensation funds. Read more
SF6 gas
SF6 gas is sulphur hexafluoride: a non-flammable, chemically inert gas with a dielectric strength about 2.5 times that of air and a high arc-quenching ability. It serves as the insulating and arc-quenching medium in high-voltage circuit breakers, GIS and gas-insulated bus ducts. Read more
Spare parts
Spare parts, tools and accessories are the set of parts and materials needed for the maintenance and repair of equipment. For turbines and compressors these are filter elements, seals, bearings, valves, blades, diaphragms and rotors. The origin of parts is confirmed by catalogue numbers, markings and accompanying documents; the warranty on the supplied parts is given by the supplier. Read more
Steam turbine
A steam turbine is a heat engine in which the energy of steam expanding in nozzles and blade rows is converted into rotation of the rotor. It drives generators, compressors, pumps and fans from 8 kW to 80 MW and runs on steam of up to 540 °C and 14 MPa. Designs are condensing and back-pressure, with or without steam extraction. Read more
Substation
A substation is an electrical installation for receiving, transforming and distributing electricity: power transformers, switchgear with circuit breakers and disconnectors, protection and automation. It is classified by its highest voltage — 110, 220, 330, 500 kV — and by the type of switchgear: air-insulated, indoor or GIS. Read more

T

Technical and commercial proposal
A technical and commercial proposal is the supplier’s document in response to the customer’s enquiry, containing the technical solution with the equipment characteristics and scope of supply, deviations from the specification, price, delivery and payment terms, warranty and schedule. It is prepared from the completed data sheet and serves as the basis for comparing proposals and for the contract. Read more
Turbine generator set
A turbogenerator is a synchronous generator driven by a steam or gas turbine; a turbine generator set is the turbine, a gearbox (at high turbine speed), the generator and the lube oil, excitation and control systems on a common baseplate. It produces electricity for the grid or the plant’s own needs; the steam sets on this site are rated 2.5–80 MW. Read more

V

Vibration diagnostics
Vibration diagnostics is the measurement and analysis of the vibration of turbines, compressors and their drivers under operating conditions to detect defects: unbalance, misalignment, rubbing, bearing wear, loose fixings, surge. Vibration correction removes the cause found by in-situ rotor balancing, shaft alignment and adjustment of the supports. Read more