What is vibration diagnostics

Vibration diagnostics is the measurement and analysis of the vibration of turbines, compressors and their drivers under operating conditions to detect defects: unbalance, misalignment, rubbing, bearing wear, loose fixings, surge. Vibration correction removes the cause found by in-situ rotor balancing, shaft alignment and adjustment of the supports.

Key facts

  • Vibration is recorded during start-up, at operating modes and during coast-down.
  • Running frequency means unbalance, twice running frequency misalignment.
  • Correction means in-situ balancing, shaft alignment and support adjustment.
  • Permanent vibration monitoring follows API 670.
  • Enables condition-based rather than calendar-based repairs.

How it is done

Sensors on the bearing housings and proximity probes for relative shaft vibration record the signal during start-up, at operating conditions and during coast-down. Spectral analysis separates the components: the running frequency points to unbalance, twice running frequency to misalignment, subharmonics to oil whirl or rubbing, blade-pass frequencies to flow-path defects. Orbits, Bode plots and waterfall spectra complete the picture.

Vibration correction

In-situ balancing of the rotor in its own bearings by trial runs with correction masses; laser alignment of the turbine, gearbox, generator or compressor shafts allowing for thermal growth; adjustment of the stiffness and tightening of the supports; elimination of rubbing and coupling defects. After correction the vibration is checked at all operating modes.

Vibration monitoring systems

Permanent systems to API 670 with vibration, axial displacement and speed sensors, monitoring racks and alarm and trip limits; they are part of the turbine and compressor control systems. Maintenance includes checks of sensors and channels, calibration and updating of limits after repair.

Why

Early detection of defects by vibration allows condition-based repair planning before failure, extension of the maintenance interval and confirmation of the quality of erection and repair. On this site: vibration diagnostics and correction of gas and steam turbines and compressors of 750 kW – 80 MW and maintenance of vibration monitoring and speed control systems.

Questions and answers

What does a vibration spectrum show?

A component at running frequency points to unbalance, at twice running frequency to misalignment, subharmonics to oil whirl or rubbing, blade-pass frequencies to flow-path defects. From the combination of components, their phase and their change during start-up and coast-down the engineer determines the cause and the remedy.

How does vibration diagnostics differ from vibration monitoring?

Vibration monitoring is continuous control of vibration levels by a permanent API 670 system with alarms and trips at set limits. Vibration diagnostics is analysis of the signal by a specialist to find the cause and plan the repair. Monitoring says that vibration has risen; diagnostics explains why.

When is in-situ balancing needed?

When vibration at running frequency has risen after a repair, a rotor part replacement or because of deposits, and dismantling the machine is not justified. The rotor is balanced in its own bearings by trial runs with correction masses, and the result is checked at all operating modes.

Related terms

Updated: 2026-09-23

CallSend a request