What is compressor surge

Surge is an unstable operating mode of a centrifugal or axial compressor in which the flow and pressure oscillate with a large amplitude and the gas periodically moves backwards through the flow path. It occurs when the flow falls below the stable operating limit; it is dangerous for the flow path, seals and bearings and is prevented by anti-surge control.

Key facts

  • Occurs when flow falls below the stable operating limit.
  • Gas periodically flows back through the compressor.
  • Cycles repeat from a fraction of a hertz to several hertz.
  • A few strong cycles can send the machine into a major overhaul.
  • Protection is an anti-surge valve with about a 10 % flow margin.

How it occurs

A compressor operates stably as long as the flow exceeds a certain minimum at the given speed. If the flow falls — because a discharge valve closes, the system resistance rises or consumption drops — the flow separates from the blades, the head collapses and the system pressure becomes higher than the pressure the compressor can generate. Gas surges back through the compressor, the system pressure falls, the compressor starts delivering again — and the cycle repeats at a frequency from a fraction of a hertz to several hertz.

Causes

Flow falling below the surge limit at constant speed; a sudden rise in system resistance — a closing valve, a clogged filter or cooler; a fast shutdown at full load without opening the bypass; a change of gas composition or temperature that shifts the compressor map; incorrect anti-surge controller settings after repair or replacement of the flow path.

Symptoms and consequences

Strong low-frequency vibration of the casing and piping, bangs and rumble, pressure swings and jumps in rotor axial position, rising gas temperature. The consequences are damage to impellers and blades, destruction of dry gas seals and the thrust bearing, loosened fits; a few strong surge cycles can send the machine into a major overhaul.

How it is prevented

The anti-surge system measures flow, pressures and speed, calculates the position of the operating point relative to the surge line and, as it approaches, opens a recycle valve from discharge to suction. The control line is set with a 10 % flow margin from the surge limit. On shutdown the recycle valve opens in advance. Tuning is done on site from the actual characteristics recorded during tests.

Where it appears on this site

Anti-surge control and protection of Kobelco, Hanwha, Siemens Energy, Dresser-Rand, MHI and Howden compressors as part of the unit control system or as a separate controller on a Russian control platform; centrifugal and integrally geared compressors; vibration diagnostics and compressor service.

Questions and answers

What is compressor surge in plain words?

The compressor can no longer overcome the system pressure: the flow in the impellers breaks down, gas briefly bursts backwards, the system pressure drops and the compressor starts delivering again. The cycle repeats from a fraction of a second to several times a second, with bangs, rumble and heavy vibration, and each cycle damages the machine.

How does surge differ from rotating stall?

Rotating stall is a local flow separation in some blade passages that travels around the impeller; the overall flow is maintained, but vibration and blade stresses rise. Surge is an instability of the whole compressor-and-system with reverse gas flow. Stall often precedes surge.

What should be done after a surge event?

Review the records of vibration, rotor axial position and thrust bearing temperatures, the leakage flow of the dry gas seals and the anti-surge settings. After strong cycles the machine is stopped to inspect the thrust bearing and seals. Diagnostics are done by our vibration diagnostics team and the protection is retuned by our anti-surge control engineers.