Service for Mitsubishi Heavy Industries steam turbines and compressors

Maintenance of Mitsubishi Heavy Industries condensing and back-pressure steam turbines and compressor trains: inspections, repairs, control system adjustment. An independent service company; our engineers were trained at the manufacturers’ works. We work in Russia, Belarus, Kazakhstan and Uzbekistan.

Equipment we service
  • condensing steam turbines
  • back-pressure steam turbines
  • compressor trains

State the machine type, the model and the serial number in your request.

The manufacturer’s names and designations are given to identify the equipment we service. The trademarks belong to their owner.

Key facts

  • Condensing and back-pressure steam turbines: inspections and repairs.
  • Single-shaft and integrally geared compressor trains, single- and multi-stage.
  • Adjustment of control, protection and governing systems.
  • Our engineers were trained at the manufacturers’ works.

Mitsubishi Heavy Industries steam turbines and compressors: what these machines are

For the oil and gas and chemical industries, Mitsubishi Heavy Industries (MHI) builds centrifugal compressors and the mechanical drive steam turbines that run them: the turbine drives the compressor at variable speed, not at the constant speed of a turbine driving a generator. These machines are made by a group company, Mitsubishi Heavy Industries Compressor Corporation (MCO, Hiroshima). Steam turbines for power stations and industrial CHP plants are supplied by MHI under the Mitsubishi Power brand.

We service MHI steam turbines and compressor trains within the overall range of our service, 750 kW to 80 MW.

MHI steam turbines and compressors: design and applications (from the manufacturer’s published materials)
MachineFeaturesWhere it is used
Condensing steam turbine, including controlled-extraction designsexhaust steam is condensed under vacuum; the extraction delivers part of the steam to the plant header at a set pressuredriving compressors in ethylene and ammonia plants, on-site power generation
Back-pressure steam turbineexhaust steam goes to consumers; output depends on the process steam demandoil refining, petrochemicals, chemical plants with a steady demand for steam
Single-shaft centrifugal compressorimpellers on one shaft; horizontally split casing, or a vertically split barrel casing for high pressuresethylene plants (cracked gas, ethylene and propylene refrigeration compressors), ammonia plants (synthesis gas compressor), refineries, LNG, gas processing and transmission
Integrally geared compressorbuilt-in gearbox: pinion shafts carrying the impellers are arranged around a bull gear, and each pinion runs at its own speed, matched to its stagescompression of air, nitrogen, fuel gas and CO₂

Equipment and types of work

Types of work by Mitsubishi Heavy Industries equipment: ✓ — we carry it out
EquipmentInspectionsRepairControl system adjustment
Condensing steam turbines✓✓✓
Back-pressure steam turbines✓✓✓
Compressor trains✓✓✓

Turbine and compressor as one train: what is checked during maintenance

In a steam turbine and compressor train, many faults arise where the machines meet, so inspections and overhauls are planned for the whole train. The machines are covered by API 612 (special-purpose steam turbines, 8th edition, November 2020) and API 617 (axial and centrifugal compressors, 9th edition, 2022), but for a particular machine the manufacturer’s manual and its records come first.

  • Turbine governing and protection. Trip and throttle valve, control valves, speed governor, overspeed protection: valve travel and trip operation are checked after an overhaul and before start-up.
  • Oil system. Bearing lubrication of the turbine, the compressor and the gearbox, if there is one, is usually shared; compressors with oil seals also have a seal oil system. Such systems are covered by API 614 (6th edition, February 2022). Oil cleanliness, filters, pumps and accumulators are checked.
  • Compressor seals. Oil seals or dry gas seals; for dry gas seals, seal gas filtration and temperature matter (API 692).
  • Shaft train. Alignment of the train shafts allowing for thermal growth, vibration and rotor axial position — from the permanent monitoring system and during vibration diagnostics and field balancing.
  • Anti-surge protection. Valve, flow transmitters and controller: turbine speed and compressor capacity have to be controlled in step.

Spare parts for this manufacturer

Spare parts and consumables for Mitsubishi Heavy Industries turbines and compressors are selected against an enquiry stating the model and the serial number.

Without manufacturer support: what documents and data are needed

Where there is no direct support from the manufacturer, the scope of work is defined from the machine documentation and its operating data: the more complete the set, the more precise the overhaul programme and the parts list. A diagnostic survey before the overhaul is useful: it shows the condition of the equipment and spare parts and helps to define the maintenance scope and the components needed in advance.

What to attach to the request

  • the model and serial numbers of the turbine and the compressor, the turbine type (condensing, back-pressure, extraction), steam conditions and operating speed;
  • the operating manual, general arrangement drawings and the spare parts list with catalogue numbers;
  • records of recent overhauls: clearances, alignment, parts replaced;
  • trends of vibration, axial position and bearing temperatures;
  • the type of control system and governor, and software versions if known.

Without the original software and direct support from the manufacturer, modelling and simulator testing before work on site become a mandatory stage of our projects. For example, testing of the digital model of a 2.4 MW Howden steam turbine has been completed to prepare the control system for commissioning. How such models are built is described on the digital twins and simulators page.

Control system

Planning a train outage: turbine, compressor, gearbox

When a steam turbine and a compressor run as a single train, the outage is planned for the whole shaft line at once: opening one machine without checking the other almost always means a second outage. The scope of work includes the turbine, the compressor, the gearbox (if any), the couplings and the lube oil system; alignment and clearance measurements are taken before disassembly and after reassembly to see what has changed.

Control system work is planned separately: checks of protections, governors and start-up sequences are conveniently combined with the outage, and where there is no original software they are rehearsed on a digital model in advance. Spare parts and tooling for the whole train are ordered against a single schedule so that the downtime is set by the scope of work, not by waiting for parts.

Questions and answers

Are you an authorised service partner of Mitsubishi Heavy Industries?

No. Energy Management LLC is an independent service company; the Mitsubishi Heavy Industries name is given to identify the equipment we service. We carry out maintenance and repairs on request or to the scope of the operating manual, using the machine documentation held by the customer. The scope and programme of work are agreed with the customer after reviewing the documentation and, if needed, a diagnostic survey.

How does maintenance of a condensing turbine differ from that of a back-pressure turbine?

A condensing turbine has a condenser and a vacuum system, and its last stages operate in wet steam. An inspection therefore includes a separate check of the last-stage blades for erosion and of the vacuum system for air in-leakage. A back-pressure turbine exports steam to the plant header, so its shutdown is coordinated with the plant steam balance: during the overhaul, consumers are usually supplied through a pressure-reducing and desuperheating station.

Do you service Mitsubishi gas turbines?

Our service list for Mitsubishi Heavy Industries equipment covers condensing and back-pressure steam turbines and compressor trains. The gas turbines on the list are small and medium-sized Siemens Energy industrial gas turbines. If you operate a gas turbine from another manufacturer, send us the model, serial number and a description of the task, and we will tell you how we can help.

Other manufacturers

Manufacturer names and designations are given to identify the equipment we service. Trademarks belong to their respective owners. Energy Management LLC is an independent service company.

CallSend a request
Service requestRequest a quotationData sheet