High-voltage equipment 110–550 kV: circuit breakers and GIS
Dead-tank and live-tank SF6 circuit breakers for 72.5–550 kV and gas-insulated switchgear for 145, 245 and 330–550 kV. The assembly plant is designed to build up to 350 circuit breakers a year; the service centre supports the equipment throughout its life. Versions for operation from −60 to +55 °C.

Choose the network class and only the matching circuit breakers, GIS, service and testing remain below. The ← → keys switch classes
For the class 220 kV
For the 72.5 kV class we supply circuit breakers; GIS starts at 145 kV. For 750 kV we offer service and testing with resonant test systems.
Sections

SF6 circuit breakers 110–500 kV: dead-tank and live-tank
We supply dead-tank SF6 circuit breakers 3AP1 DT and 3AP2 DT and live-tank breakers 3AP1 FG and 3AP2 FI for a highest operating voltage of 72.5–550 kV: rated current up to 5,000 A, breaking current up to 63 kA, spring-operated mechanism. The assembly plant can build up to 350 breakers a year; a version for service from −60 to +55 °C is available; our service centre supports the equipment over its whole life.

Gas-insulated switchgear 145, 245 and 330–550 kV
Gas-insulated switchgear for 110, 220, 330 and 500 kV networks: bays for 145, 245 and 330/550 kV with a short-circuit current of 40–63 kA and a busbar current up to 6,300 A. SF6 leakage is no more than 0.1% a year, service life is over 50 years and the first visual inspection falls due after 9 years. GIS takes 25–30 times less space than an air-insulated switchyard and can be extended without interrupting operation.
Quick selection by voltage class
Network class and the maximum operating voltage of the apparatus: 110 → 145 kV, 220 → 245 kV, 330 → 362 kV, 500 → 550 kV.
| Network class | Dead-tank 3AP DT | Live-tank 3AP FG / FI | GIS |
|---|---|---|---|
| 110 kV (145 kV) | 3AP1 DT · 3,150 A · 40 kA | 3AP1 FG · 4,000 A · 40 kA | 145 kV bay · 3,150 A · 40 kA |
| 220 kV (245 kV) | 3AP1 DT · 4,000 A · 63 kA | 3AP1 FG · 4,000 A · 50 kA | 245 kV bay · 3,150 A · 50 kA |
| 330 kV (362 kV) | 3AP2 DT · 4,000 A · 63 kA | 3AP2 FI · 5,000 A · 63 kA | 330/550 kV bay · 4,000 A · 63 kA |
| 500 kV (550 kV) | 3AP2 DT · 4,000 A · 63 kA | 3AP2 FI · 5,000 A · 63 kA | 330/550 kV bay · 4,000 A · 63 kA |
How GIS differs from a circuit breaker
A circuit breaker is a single device that switches one circuit. GIS is complete switchgear: circuit breakers, disconnectors, instrument transformers and busbars sit in sealed earthed enclosures filled with SF6 gas. It takes 25–30 times less space than air-insulated switchgear and lasts over 50 years.
Project

Rosseti: GIS for the 220 kV TsRP substation in Krasnoyarsk
1,920 sets of GIS equipment
Service and the test laboratory

Service for high-voltage equipment 110–750 kV
We service GIS, SF6 circuit breakers, disconnectors and earthing switches, current and voltage transformers and surge arresters rated 110–750 kV: preliminary inspection, diagnostic survey, maintenance without pumping out the SF6, complex repair at the works, emergency stock, upgrades, installation supervision and training. Testing is done by our own test laboratory up to 750 kV. We operate in Russia, Belarus, Kazakhstan and Uzbekistan.

High-voltage test laboratory: on-site testing of 110–750 kV equipment
We test GIS, SF6 circuit breakers, disconnectors and current and voltage transformers at the installation site with two mobile resonant test systems, WRV 3.6/680 M and WRV 1.5/680 G. The laboratory is registered with Rostechnadzor (certificate No. 9834 of 20 December 2024). We travel to substations in Russia and the countries where we work.
Questions and answers
After how many years does GIS need its first inspection?
For the GIS in our catalogue, the first visual inspection is due after 9 years in service; for equipment from other manufacturers, the intervals are taken from the operating manual. Under the service contract, the preliminary inspection is carried out when the contract is signed, a diagnostic survey and maintenance on request or after 12 years, and complex repair on request or after 25 years.
Can switchgear be extended without an outage?
Yes — <a class="term-link" href="../glossary/gis/index.html" title="What is GIS (gas-insulated switchgear)">GIS</a> allows air-insulated switchgear to be extended and rebuilt, including without interrupting its operation.
What is the service life of GIS?
Over 50 years, with SF6 leakage of not more than 0.1% a year.
In what climatic conditions do the circuit breakers work?
From −60 to +55 °C. The insulating and arc-quenching medium of dead-tank breakers is a mixture of SF6 and refrigerant gas; pure SF6 is available on request.
Dead-tank or live-tank circuit breaker: which to choose?
In a dead-tank breaker the interrupter unit sits in an earthed tank and the built-in toroidal current transformers are mounted on the bushings — separate transformers are not needed. In a live-tank breaker the interrupter chamber is mounted on an insulator column and is live; the rated current of the 3AP2 FI reaches 5,000 A. A feature-by-feature comparison is on the SF6 circuit breakers page.
How many breakers can the assembly plant produce?
The assembly plant is designed to build up to 350 circuit breakers a year — dead-tank and live-tank.