Service for Siemens Energy SST steam turbines and STC compressors
An independent service company: maintenance, medium and major overhauls of Siemens Energy SST-060 – SST-900 steam turbines and STC compressors, original spare parts and control system upgrades. The company specialises in Siemens Energy and Dresser-Rand equipment; our engineers were trained at the manufacturers’ works. We work in Russia, Belarus, Kazakhstan and Uzbekistan.
- SST-060
- SST-110
- SST-150
- SST-300
- SST-350
- SST-400
- SST-500
- SST-600
- SST-700
- SST-800
- SST-900
- STC-SH
And 12 more models — in the check below and in the spare parts catalogue.
The manufacturer’s names and designations are given to identify the equipment we service. The trademarks belong to their owner.
Key facts
- Steam turbines in 11 frame sizes: SST-060, 110, 150, 300, 350, 400, 500, 600, 700, 800, 900.
- STC compressors of 13 types: SH, SV, SR, SX, SP, STO, GV, GVT, GC, GT, GTO, GO, SOF.
- Medium and major overhauls to the manufacturer’s manual or based on diagnostic findings.
- Original spare parts: we confirm the origin by catalogue numbers, markings and accompanying documents.
- Control system upgrades with logic transfer to SIMATIC PCS7, TIA Portal or the Ezan platform.
Equipment and types of work
| Equipment | Inspections | Medium and major overhauls | Spare parts | Control system upgrades |
|---|---|---|---|---|
| SST-060 – SST-900 steam turbines | ✓ | ✓ | ✓ | ✓ |
| STC compressors | ✓ | ✓ | ✓ | ✓ |
SST and STC models: manufacturer data
The nameplate designation indicates the class of machine: Siemens SST steam turbines differ in output and layout, and STC turbocompressors in design (single-shaft and integrally geared centrifugal, axial) and duty. The data come from the manufacturer’s catalogues; the scope of work depends on the documentation and condition of the specific machine.
| Models | Output | Layout |
|---|---|---|
| SST-060, SST-110 | up to 6 MW and 7 MW | integral gearbox; the SST-110 has two casings on one gearbox |
| SST-150 | up to 20 MW | single casing, geared generator drive |
| SST-300, SST-400 | up to 50 MW and 65 MW | single casing, geared generator drive, up to two controlled extractions |
| SST-500 | up to 100 MW | double-flow condensing, usually the low-pressure casing of a two-casing arrangement |
| SST-600 | up to 100 MW | single casing, drives a generator, compressor or pump |
| SST-800 | up to 150 MW | single casing, reverse flow, direct generator drive |
| SST-700 | up to 175 MW | two modules: geared high-pressure and low-pressure |
| SST-900 | up to 250 MW and above | single casing; the reheat version has two casings |
The 2021 catalogue lists the SST-600 and SST-800 at up to 200 MW. The company’s turbine and compressor service covers machines rated from 750 kW to 80 MW. In the 2019 catalogue, the SST-350 is a single-stage turbine of the Dresser-Rand range (D-R SST 350/500/700); the numbers 500 and 700 coincide with multistage SST models, so we confirm the model by its serial number.
| Types | Design | Applications |
|---|---|---|
| STC-SH, STC-SV | single-shaft centrifugal, up to 10 impellers; horizontally split (SH) or vertically split casing (SV, up to 1,000 bar); API 617 | oil and gas, petrochemicals, refineries, fertilisers |
| STC-SX, STC-SR | axial (SX) and axial-radial (SR) for large air flows | blast furnace air, catalytic cracking, air separation |
| STC-SP | single-stage overhung with an axial inlet | polyethylene and polypropylene, gas boosting |
| STC-GV, STC-GVT, STC-GC | integrally geared: up to eight stages around a central bull gear; the GVT adds expander stages | air separation, hydrocarbons, ammonia, refineries |
| STC-GT | geared process gas turbine that drives a compressor or generator | terephthalic and nitric acid production |
| STC-SOF, STC-GO, STC-GTO, STC-STO | single-stage; in the STC-STO the compressor and steam turbine share one rotor | metallurgy, chemicals: sulphuric acid, coke oven gas |
Experience with Siemens Energy equipment
Experience with Siemens Energy machines is confirmed by a customer’s letter of appreciation and a company news item.
- STC-SV compressors. In July 2023, the company’s specialists carried out a scheduled Level 1 inspection of two Siemens STC-SV turbocompressors at the facilities of the condensate treatment plant of Gazprom Pererabotka LLC. GSP Remont LLC acknowledged the work in a letter of appreciation dated 6 October 2023.
- Equipment from the Brno works. In July 2024, the company’s order book included rotating equipment from the Siemens Energy s.r.o. works in Brno (Czech Republic), which manufactures industrial steam turbines.
Spare parts for this manufacturer
A catalogue of SST and STC models and part groups from filter elements to flow path components. Enquiries state the model and the serial number.
Control system
Testing the control system on a digital model
Where neither the original software nor direct support from the manufacturer is available, the control system is tested on a digital model of the machine before work on site: modelling and simulator testing is becoming a mandatory stage of the company’s projects. For example, testing of the digital model of a 2.4 MW Howden steam turbine was completed to prepare the control system for commissioning.
Medium and major overhaul: how we plan an outage
An overhaul outage is planned from diagnostic results, not from the calendar. Several months before the outage we carry out a survey and draw up a scope of work statement from it: which components are opened, which parts are replaced by running hours and which on condition after measurements. Spare parts are ordered against the statement allowing for lead times; tooling, fixtures and the crew are selected; the schedule is coordinated with other work on site.
During the outage we keep a daily report: operations performed, clearance and run-out measurements, deviations found and decisions taken. After reassembly — trial starts, checks of protections and governors, vibration balancing and an acceptance record with actual parameters. This procedure keeps the outage on schedule and leaves no unrecorded findings for next time.
Documents after the repair
On completion the customer receives a report with measurements before and after the repair, the list of replaced parts with catalogue numbers and their documents, test and trial run records, and recommendations for the next outage. We keep a copy of the report so that the trend can be compared at the next inspection.
Questions and answers
What does a medium or major overhaul of a steam turbine include?
The scope follows the operating manual and the diagnostic findings: opening the casing, inspecting the flow path, bearings, seals and the governing system, replacing worn parts, <a class="term-link" href="../glossary/vibration-diagnostics/index.html" title="What is vibration diagnostics">alignment</a> and balancing. We agree the programme against the actual condition of the machine.
Can I order a new steam turbine or compressor from you?
Yes. Steam turbines from 8 kW to 80 MW and centrifugal, integrally geared, reciprocating, screw and diaphragm compressors are selected for the task and described in the Equipment section; our service engineers support installation and commissioning. For Siemens Energy machines already in operation, we carry out inspections, repairs, spare parts supply and control system upgrades.
What information is needed for a service request for an SST turbine or an STC compressor?
The model and serial number from the nameplate, running hours, the type of work — inspection, repair, spare parts or control system — and any signs of malfunction. Reports on the latest repairs also help. For spare parts, give the catalogue numbers or part names and quantities. Response and call-out times are agreed with the customer for each request and kept as short as possible.
How does an STC-GV integrally geared compressor differ from a single-shaft STC-SH?
In the single-shaft STC-SH, up to ten impellers sit on one shaft and run at the same speed. In the integrally geared STC-GV, up to eight stages are mounted on high-speed pinion shafts around a central bull gear: each shaft has its own speed, and intercoolers are usually fitted between the stages. Servicing an STC-GV therefore also covers the gear mesh and the pinion shaft bearings.
Other manufacturers