What is a steam turbine
A steam turbine is a heat engine in which the energy of steam expanding in nozzles and blade rows is converted into rotation of the rotor. It drives generators, compressors, pumps and fans from 8 kW to 80 MW and runs on steam of up to 540 °C and 14 MPa. Designs are condensing and back-pressure, with or without steam extraction.
Key facts
- Steam energy turns into rotor rotation in nozzles and blades.
- Types: condensing, back-pressure and controlled extraction.
- Ratings on this site: 8 kW to 80 MW, steam up to 540 °C and 14 MPa.
- Built to API 611, API 612 and NEMA SM23.
- Speed is 1,000–15,000 rpm; generators are driven through a gearbox.
How it works
Steam from the boiler passes through the trip and governor valves into the first-stage nozzles, where its pressure turns into velocity; the flow gives its energy to the rotor blades. In a multistage turbine the expansion is shared between dozens of stages, so the flow velocity in each is moderate and the internal efficiency is high. Small single-stage turbines with a Curtis wheel are simpler and cheaper but less efficient. Speed ranges from 1,000 to 15,000 rpm; a gearbox is fitted for generators and slow-running machines.
Types by exhaust
Condensing turbines expand the steam to vacuum in a condenser (0.005–0.3 MPa abs.) and give the most electricity. Back-pressure turbines exhaust steam at 0.25–4.0 MPa (up to 6.5 MPa for drive machines) for process use — this is how a CHP plant or a works boiler house operates. Extraction turbines combine both modes. Drive machines of 8 kW – 50 MW turn compressors, boiler feed and cooling water pumps, fans and induced-draught fans; 2.5–80 MW turbine generator sets produce electricity.
Ratings and standards
Inlet steam up to 540 °C and 14 MPa(a); built to API 611 (general-purpose turbines) and API 612 (special-purpose turbines for the oil and gas industry) and NEMA SM23; packaged on a common baseplate with the lube oil and control systems. The small RLA and RLVA series go up to 745 kW, RLH up to 1,865 kW at 6,000 rpm, steam up to 510 °C and 97 bar. NEMA class A speed governors, a quick-closing trip valve separate from the governor valve.
Where it is used
Refining and petrochemicals, pulp and paper mills, metallurgy, industrial power and CHP plants, shipbuilding. On this site: drive turbines, turbine generator sets and small turbines, as well as service and spare parts for Siemens Energy, Dresser-Rand, Howden and MHI machines.
Maintenance
Overhaul of the flow path and seals, replacement of diaphragms and blades, bearing repair, balancing and alignment, tuning of governing and protection. Diagnostics from vibration and steam parameters allow major overhauls to be planned by condition. An example of work with a digital model: testing of the digital model of the 2.4 MW Howden steam turbine has been completed to prepare the control system for commissioning.
Questions and answers
How does a steam turbine work in simple terms?
Steam from the boiler accelerates in stationary nozzles and strikes the rotor blades, making the rotor turn — the way water turns a mill wheel. There can be dozens of stages: in each the steam expands a little and gives up part of its energy. The turbine shaft drives a generator, compressor, pump or fan.
How does a drive turbine differ from a turbine generator set?
A drive turbine turns a driven machine directly — a compressor, pump or fan — and changes speed with the load; on this site these are 8 kW – 50 MW machines. A turbine generator set turns a generator at constant speed to produce electricity; on this site 2.5–80 MW.
Which standards apply to steam turbines for oil and gas?
API 611 covers general-purpose turbines, for example for pumps and fans, and API 612 covers special-purpose turbines for critical machines, above all compressors. NEMA SM23 sets requirements for speed governors. The drive turbines on this site are built to API 611/612.
Related terms
Updated: 2026-09-23