What is a condensing steam turbine

A condensing turbine is a steam turbine in which the steam expands to below atmospheric pressure and enters a condenser: exhaust 0.005–0.3 MPa abs. The deeper the vacuum, the more work is obtained from each tonne of steam, so condensing machines give the most electricity, but all the exhaust heat is rejected to cooling water.

Key facts

  • Steam expands to vacuum: exhaust at 0.005–0.3 MPa abs.
  • Gives the most electricity from every tonne of steam.
  • The heat of condensation goes to cooling water or air.
  • Needs a condenser, a cooling system and water treatment.
  • On this site: 2.5–80 MW turbine generator sets and drive turbines.

How it is built

After the last stage the steam enters the condenser — a heat exchanger cooled by cooling-tower or river water or by air; the steam turns into condensate, the volume drops thousands of times and a vacuum forms in the condenser. Condensate and feed pumps return the water to the boiler. The last stages run on wet steam with long blades, so they are designed with erosion protection; controlled extraction from the middle stages supplies process steam while keeping the condensing mode.

When it is chosen

When the maximum electricity output is needed and there is little or no demand for process steam: 2.5–80 MW turbine generator sets at power stations and in captive generation, the steam part of combined-cycle plants, the drive of large compressors where cooling water is available. The electrical efficiency of a condensing plant is lower than that of a combined-cycle plant because the heat of condensation is lost.

How it differs from a back-pressure turbine

A back-pressure turbine exhausts steam at 0.25–4.0 MPa to consumers and has no condenser: it is simpler, cheaper and more efficient in overall fuel use, but its output depends on the consumers’ steam demand. A condensing turbine is independent of the heat load and produces more electricity, but needs a condenser, a cooling system and water treatment.

Ratings on this site

Turbine generator sets of 2.5–80 MW: exhaust 0.005–0.3 MPa(a), inlet steam up to 540 °C and 14 MPa(a), speed 3,000–11,000 rpm, downward, upward or axial exhaust; condensing drive turbines of 8 kW – 50 MW with and without extraction.

Questions and answers

Why is there a vacuum in the condenser?

The lower the pressure after the last stage, the larger the pressure drop used in the turbine and the more work each tonne of steam gives. The vacuum forms by itself: on condensation the steam volume falls thousands of times, while ejectors or vacuum pumps remove non-condensable gases.

Condensing or back-pressure turbine — which to choose?

If the plant needs process steam, a back-pressure turbine pays better because it uses the fuel almost completely. If consumers need little steam but a lot of electricity, a condensing turbine is chosen. An extraction turbine combines both modes.

Which condensing turbines are on this site?

Turbine generator sets of 2.5–80 MW with exhaust at 0.005–0.3 MPa abs., inlet steam up to 540 °C and 14 MPa abs. and speeds of 3,000–11,000 rpm, and condensing drive turbines of 8 kW – 50 MW with and without extraction.

Related terms