Compressors · type

Diaphragm compressors up to 45 MPa

Diaphragm compressors for pure, hazardous, rare and corrosive gases: discharge pressure up to 45 MPa, flow up to 1,000 Nm³/h, power up to 200 kW, vertically and horizontally split heads. The gas is separated from the hydraulic oil by a metal diaphragm and does not come into contact with the atmosphere — compression without contamination or leakage.

Discharge pressureup to 45MPaFlowup to 1,000Nm³/hPowerup to 200kWSplitvertical and horizontal
photo: diaphragm compressor

Key facts

  • Discharge pressure up to 45 MPa at flows up to 1,000 Nm³/h.
  • Driver power up to 200 kW.
  • The gas is separated from the oil by a diaphragm and has no contact with the atmosphere: gas purity is preserved and there is no leakage to the environment.
  • Gases: hydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases.
  • Vertically or horizontally split head — depending on maintenance conditions.
  • Diaphragm integrity monitoring: alarm on diaphragm failure.

Specifications

Diaphragm compressors: limiting data
ParameterValue
Discharge pressureMPaup to 45
Volume flowNm³/hup to 1,000
PowerkWup to 200
Designvertically and horizontally split
Gases handledhydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases
Gas contact with oil and atmosphereexcluded

Design features

Principle
the piston of the hydraulic section deflects a diaphragm set through the oil, and the diaphragms compress the gas in the head cavity
Diaphragms
a set of several metal diaphragms with a failure detection system between them
Head
vertically or horizontally split; materials selected for corrosion resistance to the gas
Stages
one or two compression stages with intercooling
Valves
suction and discharge valves in the head, made of gas-resistant materials
Driver
electric motor

How a diaphragm compressor compresses gas without contact with the lubricant

The gas and the oil are on opposite sides of a metal diaphragm set, and the gas side has no moving seals. Oil therefore cannot reach the gas even when the rings of the hydraulic piston wear.

  • Hydraulic circuit. The piston forces oil through a perforated plate beneath the diaphragm set. On every stroke a compensating pump makes up the oil that leaks past the piston, and the excess returns through an overflow valve. The valve is set slightly above the maximum gas discharge pressure, so the diaphragm reaches the contour of the gas cavity on every stroke and sweeps out virtually all the gas.
  • Gas side. The gas is compressed in a shallow cavity between the diaphragm and the concave surface of the gas plate, and is contained by static head seals. The heat of compression passes out through the walls of the cooled head.

The diaphragm sweeps only a small volume per stroke, so diaphragm machines have a modest capacity: the compressors on this page deliver up to 1,000 Nm³/h.

Diaphragm service life: what it depends on

Diaphragms are replaced at the interval given in the manufacturer’s manual, or earlier when the integrity monitoring system raises an alarm. How long a set lasts before replacement depends largely on operating conditions. Diaphragm life is shortened by:

  • solid particles such as scale, swarf left after installation and dust: they collect at the edge of the cavity and create stress concentrations, so a suction filter is needed;
  • oil shortage caused by a faulty compensating pump, or a wrongly set overflow valve;
  • operation above the design pressure, which accelerates diaphragm fatigue from cyclic loading;
  • hydraulic oil contaminated with dirt or water.

It makes sense to keep a set of diaphragms, valves and head seals in the site spare parts stock, especially if there is no standby compressor.

Applications

Duties

  • high-purity hydrogen compression for storage, fuelling and process use
  • CO₂ and hydrogen chloride compression
  • rare gases: helium, argon and others where leakage and contamination are unacceptable
  • hazardous and corrosive gases at chemical plants

Industries

Which gases diaphragm compressors handle and what to consider

A diaphragm compressor is chosen when the gas is expensive, hazardous or must stay pure, and the flow is small.

Gases for diaphragm compressors: why a diaphragm machine and what to consider
GasWhy a diaphragm compressorWhat to consider
Hydrogenfuel cell vehicles need a purity of at least 99.97% with no more than 2 µmol/mol of hydrocarbons other than methane (ISO 14687:2025, grade D), so oil in the gas is unacceptablematerials resistant to hydrogen embrittlement; explosion-protected design
CO₂oil-free compression where gas purity mattersthe critical point is 7.38 MPa and 31 °C: near it the gas properties change sharply, and if the gas is cooled below 31 °C between stages it may condense, so exact suction and discharge pressures and temperatures are needed for selection
Hydrogen chloridea toxic gas, leakage is unacceptablewith moisture it forms hydrochloric acid, so materials are chosen according to the moisture content of the gas
Helium, argon and other rare gaseslosses of expensive gas; helium escapes easily through any leak pathpurity at the outlet, for example when filling cylinders
Toxic and corrosive gasesno emissions to atmosphere in normal operation, which matters in chemical plantsmaterials of the cavity, diaphragms and valves suited to the gas; where gas from the diaphragm monitoring system is vented

Diaphragm or reciprocating compressor for hydrogen

Flow decides. For pure hydrogen at up to 1,000 Nm³/h and up to 45 MPa, a diaphragm compressor is simpler: the gas never touches oil, and there is no rod packing to leak. For higher flows and pressures up to 50 MPa, a reciprocating compressor to API 618 is chosen, with non-lubricated cylinders where the gas must stay pure. All three types, including centrifugal machines, are compared on the Hydrogen compressors page.

Diaphragm and reciprocating compressors for hydrogen: operating differences
ParameterDiaphragmReciprocating
Pressure and flow of the machines on this siteup to 45 MPa, up to 1,000 Nm³/hup to 50 MPa, up to 115,000 m³/h
Gas leak pathno moving seals on the gas siderod packing with leak-off vent
Sensitivity to particleshigh: particles damage the diaphragmlower, but particles accelerate wear of rings and valves
Main wearing partsdiaphragm set, valves, head sealspiston rings, rod packing, valves

Documents

Brochure “Compressor equipment”

PDF

PDF
Enquiry data sheet: compressor

DOCX · fill in online

DOCX

Sources: the data come from the company’s current website. Diaphragm compressors are not covered by a separate API standard; material and testing requirements are set in the customer’s data sheet.

Questions and answers

How does a diaphragm compressor differ from a reciprocating one?

In a reciprocating compressor the gas is compressed directly by the piston and contacts the rings and lubricant. In a diaphragm compressor the piston acts on oil, and the oil deflects a metal diaphragm that compresses the gas: the gas touches neither the oil nor the atmosphere.

Which gases is it intended for?

Hydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases, where purity and zero leakage matter.

What pressure and flow are achievable?

Diaphragm compressors: up to 45 MPa at flows up to 1,000 Nm³/h; driver power up to 200 kW. Integrally geared compressors: up to 10 MPa and up to 160,000 m³/h at up to 30 MW; the pressure ratio in one machine is up to 35.

What happens if the diaphragm fails?

The diaphragm is a set of several sheets; the detection system registers the failure of one sheet and raises an alarm before the gas can mix with the oil.

Is 45 MPa enough for a hydrogen refuelling station?

For fuelling vehicles with 35 MPa tanks, yes. Under the SAE J2601 protocol the maximum tank pressure during such fuelling is 43.8 MPa, or 125% of the nominal working pressure, so compressors at these stations are typically rated for 45 MPa. When 70 MPa tanks are fuelled, the pressure can reach 87.5 MPa, which is above the range of the machines on this page.

Expert in charge

Rotating equipment service

Manufacturers’ names and designations are used to identify the equipment we supply and service. Trademarks belong to their respective owners. Energy Management LLC is an independent engineering company.

CallSend a request