Diaphragm compressors up to 45 MPa
Diaphragm compressors for pure, hazardous, rare and corrosive gases: discharge pressure up to 45 MPa, flow up to 1,000 Nm³/h, power up to 200 kW, vertically and horizontally split heads. The gas is separated from the hydraulic oil by a metal diaphragm and does not come into contact with the atmosphere — compression without contamination or leakage.
Key facts
- Discharge pressure up to 45 MPa at flows up to 1,000 Nm³/h.
- Driver power up to 200 kW.
- The gas is separated from the oil by a diaphragm and has no contact with the atmosphere: gas purity is preserved and there is no leakage to the environment.
- Gases: hydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases.
- Vertically or horizontally split head — depending on maintenance conditions.
- Diaphragm integrity monitoring: alarm on diaphragm failure.
Specifications
| Parameter | Value |
|---|---|
| Discharge pressureMPa | up to 45 |
| Volume flowNm³/h | up to 1,000 |
| PowerkW | up to 200 |
| Design | vertically and horizontally split |
| Gases handled | hydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases |
| Gas contact with oil and atmosphere | excluded |
Design features
- Principle
- the piston of the hydraulic section deflects a diaphragm set through the oil, and the diaphragms compress the gas in the head cavity
- Diaphragms
- a set of several metal diaphragms with a failure detection system between them
- Head
- vertically or horizontally split; materials selected for corrosion resistance to the gas
- Stages
- one or two compression stages with intercooling
- Valves
- suction and discharge valves in the head, made of gas-resistant materials
- Driver
- electric motor
How a diaphragm compressor compresses gas without contact with the lubricant
The gas and the oil are on opposite sides of a metal diaphragm set, and the gas side has no moving seals. Oil therefore cannot reach the gas even when the rings of the hydraulic piston wear.
- Hydraulic circuit. The piston forces oil through a perforated plate beneath the diaphragm set. On every stroke a compensating pump makes up the oil that leaks past the piston, and the excess returns through an overflow valve. The valve is set slightly above the maximum gas discharge pressure, so the diaphragm reaches the contour of the gas cavity on every stroke and sweeps out virtually all the gas.
- Gas side. The gas is compressed in a shallow cavity between the diaphragm and the concave surface of the gas plate, and is contained by static head seals. The heat of compression passes out through the walls of the cooled head.
The diaphragm sweeps only a small volume per stroke, so diaphragm machines have a modest capacity: the compressors on this page deliver up to 1,000 Nm³/h.
Diaphragm service life: what it depends on
Diaphragms are replaced at the interval given in the manufacturer’s manual, or earlier when the integrity monitoring system raises an alarm. How long a set lasts before replacement depends largely on operating conditions. Diaphragm life is shortened by:
- solid particles such as scale, swarf left after installation and dust: they collect at the edge of the cavity and create stress concentrations, so a suction filter is needed;
- oil shortage caused by a faulty compensating pump, or a wrongly set overflow valve;
- operation above the design pressure, which accelerates diaphragm fatigue from cyclic loading;
- hydraulic oil contaminated with dirt or water.
It makes sense to keep a set of diaphragms, valves and head seals in the site spare parts stock, especially if there is no standby compressor.
Applications
Duties
- high-purity hydrogen compression for storage, fuelling and process use
- CO₂ and hydrogen chloride compression
- rare gases: helium, argon and others where leakage and contamination are unacceptable
- hazardous and corrosive gases at chemical plants
Which gases diaphragm compressors handle and what to consider
A diaphragm compressor is chosen when the gas is expensive, hazardous or must stay pure, and the flow is small.
| Gas | Why a diaphragm compressor | What to consider |
|---|---|---|
| Hydrogen | fuel cell vehicles need a purity of at least 99.97% with no more than 2 µmol/mol of hydrocarbons other than methane (ISO 14687:2025, grade D), so oil in the gas is unacceptable | materials resistant to hydrogen embrittlement; explosion-protected design |
| CO₂ | oil-free compression where gas purity matters | the critical point is 7.38 MPa and 31 °C: near it the gas properties change sharply, and if the gas is cooled below 31 °C between stages it may condense, so exact suction and discharge pressures and temperatures are needed for selection |
| Hydrogen chloride | a toxic gas, leakage is unacceptable | with moisture it forms hydrochloric acid, so materials are chosen according to the moisture content of the gas |
| Helium, argon and other rare gases | losses of expensive gas; helium escapes easily through any leak path | purity at the outlet, for example when filling cylinders |
| Toxic and corrosive gases | no emissions to atmosphere in normal operation, which matters in chemical plants | materials of the cavity, diaphragms and valves suited to the gas; where gas from the diaphragm monitoring system is vented |
Diaphragm or reciprocating compressor for hydrogen
Flow decides. For pure hydrogen at up to 1,000 Nm³/h and up to 45 MPa, a diaphragm compressor is simpler: the gas never touches oil, and there is no rod packing to leak. For higher flows and pressures up to 50 MPa, a reciprocating compressor to API 618 is chosen, with non-lubricated cylinders where the gas must stay pure. All three types, including centrifugal machines, are compared on the Hydrogen compressors page.
| Parameter | Diaphragm | Reciprocating |
|---|---|---|
| Pressure and flow of the machines on this site | up to 45 MPa, up to 1,000 Nm³/h | up to 50 MPa, up to 115,000 m³/h |
| Gas leak path | no moving seals on the gas side | rod packing with leak-off vent |
| Sensitivity to particles | high: particles damage the diaphragm | lower, but particles accelerate wear of rings and valves |
| Main wearing parts | diaphragm set, valves, head seals | piston rings, rod packing, valves |
Related
Documents
Sources: the data come from the company’s current website. Diaphragm compressors are not covered by a separate API standard; material and testing requirements are set in the customer’s data sheet.
Questions and answers
How does a diaphragm compressor differ from a reciprocating one?
In a reciprocating compressor the gas is compressed directly by the piston and contacts the rings and lubricant. In a diaphragm compressor the piston acts on oil, and the oil deflects a metal diaphragm that compresses the gas: the gas touches neither the oil nor the atmosphere.
Which gases is it intended for?
Hydrogen, CO₂, hydrogen chloride, hazardous, rare and corrosive gases, where purity and zero leakage matter.
What pressure and flow are achievable?
Diaphragm compressors: up to 45 MPa at flows up to 1,000 Nm³/h; driver power up to 200 kW. Integrally geared compressors: up to 10 MPa and up to 160,000 m³/h at up to 30 MW; the pressure ratio in one machine is up to 35.
What happens if the diaphragm fails?
The diaphragm is a set of several sheets; the detection system registers the failure of one sheet and raises an alarm before the gas can mix with the oil.
Is 45 MPa enough for a hydrogen refuelling station?
For fuelling vehicles with 35 MPa tanks, yes. Under the SAE J2601 protocol the maximum tank pressure during such fuelling is 43.8 MPa, or 125% of the nominal working pressure, so compressors at these stations are typically rated for 45 MPa. When 70 MPa tanks are fuelled, the pressure can reach 87.5 MPa, which is above the range of the machines on this page.
Expert in charge
Rotating equipment serviceManufacturers’ names and designations are used to identify the equipment we supply and service. Trademarks belong to their respective owners. Energy Management LLC is an independent engineering company.