SGT-100 · 5.1–5.7 MW
Generation 5.1 and 5.4 MWe at 30.1 and 30.3% efficiency; drive 5.7 MW at 33.1%. The generator version is single-shaft, the drive version two-shaft; NOx ≤ 15 ppm (DLE).
Siemens Energy industrial gas turbines in two groups: small SGT-100 – SGT-400 (5–15 MW) and medium SGT-600 – SGT-800 (24–62 MW). They suit power generation as well as compressor and pump drive duty in the oil and gas industry. Simple-cycle efficiency up to 41.1%, NOx with dry low emissions combustion from 9 to 25 ppm. We select the machine for the duty, supply and service it.

Seven Siemens Energy models in two groups. Manufacturer’s data: ISO conditions, simple cycle, natural gas.
| Parameter | SGT-1005.1–5.7 MW | SGT-2006.75–7.68 MW | SGT-3008.0–9.1 MW | SGT-40012.9–14.9 MW | SGT-60024.5–25.2 MW | SGT-70032.6–36.2 MW | SGT-80045.3–62.5 MW |
|---|---|---|---|---|---|---|---|
| Model | SGT-100 | SGT-200 | SGT-300 | SGT-400 | SGT-600 | SGT-700 | SGT-800 |
| Group | small | small | small | small | medium | medium | medium |
| Generation (ISO)MWe | 5.1 / 5.4 | 6.75; up to 7.68 after upgrade | 8.0 | 12.9 / 14.3 | 24.5 | 32.6 / 35.2 | 45.3 / 49.9 / 55.6 / 57.0 / 62.5 |
| Efficiency, generation% | 30.1 / 30.3 | — | 31.0 | 35.0 / 35.6 | 33.6 | 36.8 / 38.0 | 38.4 / 39.4 / 39.5 / 40.1 / 41.1 |
| Mechanical driveMW | 5.7 | — | 8.4 / 9.1 | 13.4 / 14.9 | 25.2 | 33.5 / 36.2 | — |
| Efficiency, drive% | 33.1 | — | 35.3 / 35.9 | 36.4 / 37.0 | 34.6 | 37.8 / 39.0 | — |
| Design | single-shaft (generation), two-shaft (drive) | — | single-shaft (generation), two-shaft (drive) | two-shaft | two-shaft | two-shaft | single-shaft |
| In combined cycle | — | — | — | — | — | — | SCC-800 1×1: up to 89 MW, 59.6% |
| NOx emissions (DLE)ppm at 15% O₂, gas | ≤ 15 | — | < 10 | < 10 | ≤ 9 | ≤ 15 | 15–25 |
Emissions in the table are given in ppm at 15% O₂ for operation on gas with dry low emissions (DLE) combustion: the volume fraction in dry exhaust gas, corrected to 15% oxygen. The correction makes machines with different amounts of excess air comparable.
Manufacturer’s data: SGT-100 and SGT-700 — no more than 15 ppm NOx, SGT-300 and SGT-400 — below 10 ppm, SGT-600 — no more than 9 ppm, SGT-800 — 15–25 ppm depending on the version.
Russian regulations state concentrations in mg/m³ at 0 °C and 101.3 kPa. For NOx expressed as NO₂, 1 ppm corresponds to about 2.05 mg/m³, and for CO to 1.25 mg/m³: 15 ppm NOx is about 31 mg/m³. For gas turbine units of 2.5–200 MW driving turbine generators, the reference conditions for nitrogen oxides are set by GOST 29328-92 (clause 2.8.15): dry sample, 0 °C, 0.1013 MPa, 15% O₂.
Unlike water injection, DLE needs no water treatment or constant water supply. Emissions depend on load and gas composition, so combustion tuning is carried out after burner repairs or a change of fuel.
Small machines suit captive power plants, cogeneration and compressor and pump drive at fields and compressor stations. The generator versions of SGT-100 and SGT-300 are single-shaft, the drive versions two-shaft; SGT-400 is a two-shaft machine.
Generation 5.1 and 5.4 MWe at 30.1 and 30.3% efficiency; drive 5.7 MW at 33.1%. The generator version is single-shaft, the drive version two-shaft; NOx ≤ 15 ppm (DLE).
Generation 6.75 MWe, up to 7.68 MWe after upgrade. The manufacturer currently has no separate page for this model; efficiency to be confirmed.
Generation 8.0 MWe at 31.0% efficiency, single-shaft; drive 8.4 and 9.1 MW at 35.3 and 35.9%, two-shaft; NOx < 10 ppm.
Generation 12.9 and 14.3 MWe at 35.0 and 35.6%; drive 13.4 and 14.9 MW at 36.4 and 37.0%; two-shaft; NOx < 10 ppm.
Medium machines are used in captive power plants, peaking and reserve sources, combined-cycle plants and compressor drive at production, gas transmission and LNG facilities. SGT-600 and SGT-700 are two-shaft machines, SGT-800 is single-shaft.
Generation 24.5 MWe at 33.6%; drive 25.2 MW at 34.6%; two-shaft; NOx ≤ 9 ppm.
Generation 32.6 and 35.2 MWe at 36.8 and 38.0%; drive 33.5 and 36.2 MW at 37.8 and 39.0%; two-shaft; NOx ≤ 15 ppm.
Generation 45.3, 49.9, 55.6, 57.0 and 62.5 MWe at 38.4–41.1% efficiency; single-shaft; in an SCC-800 1×1 combined-cycle plant up to 89 MW and 59.6%; NOx 15–25 ppm.
A gas turbine is selected for the site’s load profile and duty, not only for its rated output. The values in the data table apply at ISO conditions; for a real site they are corrected for climate and altitude.
| Criterion | What is compared | Models on this page |
|---|---|---|
| Output and duty | base load or peaking and reserve duty, number of starts per year | 5.1–14.3 MWe small, 24.5–62.5 MWe medium (ISO) |
| Generation or drive | a generator or a compressor or pump drive | drive versions of SGT-100, SGT-300, SGT-400, SGT-600 and SGT-700: 5.7–36.2 MW |
| Economy | simple-cycle efficiency, use of the exhaust heat | 30.1–41.1% in generation; SGT-800 in combined cycle up to 59.6% |
| Emissions | dry low emissions (DLE) combustion | NOx from ≤ 9 to 15–25 ppm |
| Fuel | gas composition, pressure upstream of the turbine, backup fuel | from the enquiry data sheet |
These data are collected in the enquiry data sheet for a gas turbine unit. For captive generation of up to a few megawatts, compare the options in the article “Gas turbine or gas engine genset”.
In simple cycle the exhaust goes to atmosphere, and the plant efficiency is practically that of the turbine itself (see the data table for the values). The hot exhaust can be used in two more ways.
For peaking and reserve plants, start-up speed matters more than efficiency: the SGT-800 units of the peaking and reserve power sources in Belarus can deliver rated output 15 minutes after a cold start.
Control systems for gas turbine units, migration from SPPA-T3000 and PCS7 to TIA Portal and the Russian Ezan platform, a digital twin for checking operating modes and training personnel.
The team has taken part in commissioning SGT-800 gas turbine units in two large projects — at three sites in Russia and Belarus — and has maintained a gas turbine control system at one more power plant.
Inspection and overhaul intervals of a gas turbine are driven mainly by the condition of its hot gas path parts: the combustor with its liners, the transition pieces, and the vanes and blades of the first stages. They are damaged by oxidation, creep and thermal fatigue, so the blades are protected with heat-resistant coatings and cooled with air from the compressor.
Work is planned by equivalent operating hours and number of starts: combustion inspection, hot gas path inspection with repair or replacement of blades, and major overhaul with full disassembly. Intervals are set by the manufacturer; the scope of each type of work is described in the glossary entry gas turbine inspection.
The company carries out minor inspections and medium and major overhauls of Siemens Energy small and medium industrial gas turbines — see gas turbine service and repair. Its partner for the repair and manufacture of gas turbine parts is Turbinaspetsservis Production Enterprise LLC (Ufa); in October 2025, at the Russian Energy Forum, the two companies gave a joint presentation on service during major overhauls of SGT-700 gas turbines, drawing on the overhaul of two turbines of power unit 5 at Berezovskaya GRES.
Supply and service — on a separate request.
42.2 MW, gross efficiency 32.2%. For captive power plants, peaking and reserve and cogeneration plants; a 50 Hz generator is connected through a gearbox.
185 MW, gross efficiency 36.4%. An E-class turbine for power plants and combined-cycle units, 3,000 rpm without a gearbox.
308 MW, gross efficiency 40.1%. An F-class turbine for power plants and combined-cycle units, 3,000 rpm without a gearbox.
They are two groups of Siemens Energy machines. SGT-100 – SGT-400 are small turbines of 5–15 MW for captive generation, cogeneration and compressor and pump drive. SGT-600 – SGT-800 are medium turbines of 24–62 MW for captive power plants, peaking and reserve sources, combined-cycle plants and compressor drive.
The two-shaft versions of SGT-100 (5.7 MW), SGT-300 (8.4 and 9.1 MW), SGT-400 (13.4 and 14.9 MW), SGT-600 (25.2 MW) and SGT-700 (33.5 and 36.2 MW). SGT-800 is a single-shaft machine for power generation.
With dry low emissions (DLE) on gas at 15% O₂: SGT-600 no more than 9 ppm NOx, SGT-300 and SGT-400 below 10 ppm, SGT-100 and SGT-700 no more than 15 ppm, SGT-800 15–25 ppm.
Company engineers trained at the manufacturers’ plants carry out <a class="term-link" href="../glossary/gas-turbine-inspection/index.html" title="What is a gas turbine inspection">minor inspections</a>, medium and major overhauls, combustion tuning and control system upgrades for Siemens Energy small and medium industrial gas turbines. Team track record: 8 SGT-800 units at Yamal LNG and 11 in Belarus.
The rating is given at ISO conditions: 15 °C, 101.3 kPa and 60% relative humidity (ISO 3977-2; in Russia GOST R 52200-2004). In hot weather the air density falls, the mass flow through the compressor drops, and output and efficiency fall with it. For a project, output is therefore corrected to the site’s design temperatures.
Expert in charge
Gas turbine serviceManufacturers' names and designations are used to identify the equipment we supply and service. Trademarks belong to their respective owners. Energy Management LLC is an independent engineering and service company.