What is mechanical drive by a turbine

Mechanical drive is the use of a steam or gas turbine to turn a working machine directly, without a generator and an electric motor: a compressor, a pump, a fan, an induced-draught fan. A drive turbine varies its speed with the load and so controls the machine’s output without throttling; the steam drive turbines on this site are rated 8 kW – 50 MW.

Key facts

  • The turbine drives a compressor, pump or fan directly, without an electric motor.
  • Output is controlled by speed rather than throttling.
  • Steam drive turbines: 8 kW – 50 MW to API 611/612.
  • The turbine keeps running during a power outage.

Why it is used

Where steam is available it is simpler and more reliable to turn a pump or a fan with a turbine than to install a motor with a frequency converter: the turbine keeps running during a power outage, draws no starting current and uses steam that then goes to the process. Gas turbine drive of compressors at gas compressor stations and LNG plants is independent of the electrical grid and runs on the gas being pumped.

Steam drive turbines

Small and medium-power steam turbines of 8 kW – 50 MW, 1,000–15,000 rpm, steam up to 540 °C and 14 MPa(a), four designs — condensing and back-pressure, with and without extraction; packaged on a common baseplate to API 611/612. The small single-stage RLA, RLVA and RLH turbines up to 1,865 kW drive boiler feed and cooling water pumps and serve as starters; the vertical-shaft RLVA mounts directly on the pump.

Gas turbine drive

A twin-shaft gas turbine with a free power turbine turns a centrifugal compressor: output is controlled by speed and the anti-surge system keeps the operating point in the safe zone. This is how feed gas and boil-off gas compressors at LNG plants work.

Design considerations

Matching the turbine and the driven machine in power and speed, a gearbox where the speeds differ, a common lube oil system, torsional analysis of the shaft line, overspeed protection on load rejection, a NEMA class A speed governor. The control system of the drive train combines turbine governing and compressor protection.

Questions and answers

Steam turbine or electric motor for a pump — which pays better?

Where steam is available a turbine often pays better: it keeps running during a power outage, draws no starting current and its exhaust steam goes to the process. A motor with a frequency converter is easier to maintain but depends on the grid. The decision rests on the plant’s steam and power balance.

Which machines do steam turbines drive?

Centrifugal compressors, boiler feed and cooling water pumps, fans and induced-draught fans, generators. The small RLA, RLVA and RLH turbines up to 1,865 kW also serve as starters, and the vertical-shaft RLVA mounts directly on the pump — see small steam turbines.

What is a torsional analysis of the shaft line?

A calculation of the torsional natural frequencies of the train “turbine — coupling — gearbox — driven machine”. It shows whether these frequencies coincide with running speeds and excitation harmonics; if they do, the coupling or shaft stiffness is changed. For critical trains the analysis is done at the design stage.