Steam turbine service and repair
We service condensing and back-pressure steam turbines by Siemens Energy (SST-060 – SST-900), Dresser-Rand (RLA, RLVA, RLHA, AVTTW, 2TA, GAF, K, R, RS, TT14, TT22, EMD), Mitsubishi Heavy Industries and Howden. Maintenance and repair on request or to the scope of the operating manual; adjustment of governing and protection systems; original spare parts.

Scope
- inspections and diagnostic survey
- maintenance on request or to the scope of the operating manual
- medium and major overhauls with inspection of the rotor and flow path
- adjustment of governing and protection systems and steam admission units
- bearings, bearing shells, seals, couplings
- vibration diagnostics and field balancing
- original spare parts
- installation supervision and commissioning
Scope of a steam turbine overhaul by component
The scope of a steam turbine overhaul is set by the manufacturer’s operating manual and the results of the diagnostic survey. For turbines at power plants, the types of repair are defined by the Rules for Organising Maintenance and Repair of Electric Power Facilities (Order of the Russian Ministry of Energy No. 1013 of 25 October 2017): a major overhaul restores serviceability and the full or nearly full service life of the machine, with any of its parts replaced or restored; a medium overhaul restores serviceability and part of the service life, with a limited range of components replaced or restored.
| Component | Work | Typical findings |
|---|---|---|
| Flow path: nozzles, diaphragms, rotating blades | opening the casing, removing deposits, inspection and non-destructive testing of blades, clearance measurements | salt deposits; water droplet erosion of last-stage blades in condensing turbines; solid particle erosion of first-stage nozzles and blades; fatigue cracks |
| Rotor | inspection of journals, discs and blade root fastenings, runout check, balancing | journal wear; unbalance, including after blade replacement |
| Shaft and diaphragm seals: labyrinth and carbon ring seals | radial clearance measurements, replacement of segments and rings | increased clearances after rubs, steam leakage |
| Bearings: journal and thrust | inspection of bearing shells and pads, clearance measurements; on small turbines, replacement of rolling bearings | wear and spalling of the bearing lining, signs of overheating |
| Steam admission and governing: stop and control valves, speed governor | overhaul of valves and actuators, lapping of seating surfaces, governor adjustment | valve stems sticking because of deposits, valve leakage, wear of governing parts |
| Protection | checks of the overspeed, axial displacement, oil pressure and vibration protection | setpoint drift, wear of overspeed trip components |
| Oil system, coupling, alignment | cleaning of the oil tank and oil coolers, filter element replacement, alignment of the shaft line with the generator or driven machine | water and sludge in the oil, misalignment |
If defects beyond the agreed scope are found once the casing is opened, we agree the work programme and the spare parts list with the customer before the work continues.
Signs that a steam turbine needs repair
Many steam turbine defects show up in operating data before the machine is shut down. The table lists typical signs and their likely causes; the actual cause is established by a diagnostic survey of the turbine.
| Sign | Likely cause | What is checked |
|---|---|---|
| output falls at the same steam flow, pressure in the monitored stages rises | salt deposits in the flow path | steam quality, condition of the flow path |
| bearing pedestal vibration increases | rotor unbalance, misalignment, bearing wear, seal rubs | vibration spectrum, alignment, bearings |
| water appears in the oil | worn shaft end seals letting steam into the bearing housings | seals and the removal of leak-off steam |
| stop or control valves stick, speed is unstable | deposits on valve stems, worn governing parts | valve travel, speed governor |
| journal bearing or thrust pad temperature rises | bearing wear, contaminated oil or insufficient oil supply | bearings, oil system |
| with the stop and control valves closed, the rotor does not come to rest | stop or control valve leakage | valve seating surfaces |
For turbine units at power plants, the Rules for the Technical Operation of Power Plants and Networks of the Russian Federation (Order of the Russian Ministry of Energy No. 1070 of 4 October 2022) limit the RMS vibration velocity of bearing pedestals to 4.5 mm/s. If this is exceeded, measures to reduce vibration must be taken within 30 days; above 7.1 mm/s the unit may run for no more than 7 days, and at 11.2 mm/s or more the turbine is tripped by the protection or manually unless the manufacturer has specified a different value.
On mechanical drive turbines, to which these Rules do not apply, and where international criteria are used, vibration severity is compared with the zones of ISO 20816-3 (industrial machinery rated above 15 kW, including steam turbines up to 40 MW) or ISO 20816-2 (steam turbines and generators above 40 MW with fluid-film bearings and rated speeds of 1500, 1800, 3000 or 3600 rpm). Measurements, spectrum analysis and field balancing of the rotor are described on the vibration diagnostics and field balancing page.
Steam turbines we service
| Manufacturer | Models | More |
|---|---|---|
| Siemens Energy | SST-060, SST-110, SST-150, SST-300, SST-350, SST-400, SST-500, SST-600, SST-700, SST-800, SST-900 | SST and STC service · Spare parts |
| Dresser-Rand | RLA, RLVA, RLHA, AVTTW, 2TA, GAF, K, R, RS, TT14, TT22, EMD | Dresser-Rand service · Spare parts |
| Mitsubishi Heavy Industries | condensing and back-pressure turbines | MHI service |
| Howden | steam turbines; testing of the digital model of a 2.4 MW Howden steam turbine has been completed to prepare its automatic control system for commissioning | Howden service |
Manufacturer names and designations are given to identify the equipment we service. Trademarks belong to their respective owners. Energy Management LLC is an independent service company.
Spare parts and control systems for the overhaul
For Siemens Energy SST-060 – SST-900 and Dresser-Rand steam turbines, we supply original spare parts and consumables, selected by model and serial number. We confirm the origin of parts by catalogue numbers, markings and accompanying documents. Every batch is inspected by our engineers before shipment: incoming inspection and cross-checking against the machine documentation.
- flow path components: rotors, diaphragm carriers, blades, nozzle blocks, sealing rings;
- stop valves and their spare parts, parts of governing and steam admission units;
- bearing assemblies, bearing shells, labyrinth and other seals, couplings, casing fasteners;
- oil system equipment and parts, filter elements, turning gear;
- sensors and proximity probes, spare parts for control, vibration monitoring, bearing temperature and rotor position monitoring systems.
Part groups by model and the ordering procedure are described in the spare parts for turbines and compressors section.
Control system. The turbine’s control, vibration monitoring and speed monitoring systems can be upgraded together with the overhaul. The company modernises and repairs control systems and offers steam turbine control systems based on a Russian hardware and software platform — see control systems for turbines and compressors. Where neither the original software nor direct support from the manufacturer is available, the control system is tested on a model before work on site. For example, testing of the digital model of a 2.4 MW Howden steam turbine has been completed to prepare its automatic control system for commissioning (news on the steam turbine digital model, 22 July 2024).
How the work proceeds
- 1
Request
Model, serial number, running hours, what happened.
- 2
Diagnostic survey
Condition of the turbine and of the governing and protection systems.
- 3
Work programme
Scope, spare parts and personnel agreed with the customer.
- 4
Execution
Repair on site or in the workshop, governor adjustment.
- 5
Report
Technical report, recommendations, plan for the next inspections.
Tests after repair and acceptance
After a major overhaul, the turbine is returned to service only once its protection, valves and governing system have been checked. For steam turbines at power plants, these checks are set out in Chapter XIX of the Rules for the Technical Operation of Power Plants and Networks; they are performed to the manufacturer’s instructions and a programme approved by the facility’s technical manager.
- Overspeed protection. Unless the manufacturer specifies otherwise, it is tested by raising the speed above rated, among other cases after erection and after a major overhaul, before a load rejection test of the governing system and on start-up after the overspeed trip or the governing system has been dismantled. The Rules list further cases, such as start-up after a long shutdown and scheduled tests at least every 4 months.
- Valve tightness. Stop and control valves are checked after erection, before shutdown for a major overhaul, on start-up after it, before the overspeed trip test and at least once a year. The criterion is the rotor speed once the valves under test are fully closed; unless the manufacturer has set its own value, it must not exceed 50% of rated speed with rated steam conditions upstream of the valves and rated exhaust pressure.
- Closing time and governing characteristics. The closing time of the stop valves is checked and the governing system characteristics on a stationary turbine and at no load are recorded immediately before and after a major overhaul or a repair of the main governing and steam admission components; the data for the static characteristic under load are recorded after such a repair.
The Rules for Organising Maintenance and Repair of Electric Power Facilities add acceptance tests and a period of monitored operation that ends 30 calendar days after the equipment is put on load. On acceptance, the commission gives the repaired equipment one of three ratings: “complies with the repair documentation”, “complies with the repair documentation with limitations” or “does not comply with the repair documentation”.
On mechanical drive turbines in oil, gas and chemical plants outside the power sector, the checks follow the manufacturer’s instructions; requirements for the design, overspeed protection and testing of new machines are set by API 611 and API 612 for general-purpose and special-purpose turbines respectively.
Related pages
Questions and answers
Do you service turbine models no longer in production?
Yes: we select <a class="term-link" href="../glossary/spare-parts/index.html" title="What spare parts are and how their origin is confirmed">spare parts</a> by model and serial number, where necessary from drawings and samples, and repair to the scope of the operating manual.
What does adjustment of the governing and protection system include?
Checking and setting the speed governor, the stop and control valves, and the overspeed, axial displacement, vibration and oil pressure protections.
Do you repair at the customer's site?
Yes. <a class="term-link" href="../glossary/maintenance-and-overhaul/index.html" title="What is maintenance, medium and major overhaul">Medium overhauls</a> and adjustment are done on site; major overhauls with part restoration are done on site or in the workshop, as agreed.
Who provides the warranty on work and spare parts?
Energy Management LLC. Warranty cases are handled by our own specialists; the terms are set by the contract.
How does a medium overhaul of a steam turbine differ from a major overhaul?
In the scope of work and the share of service life restored. A medium overhaul replaces or restores a limited range of components and restores part of the service life. A major overhaul may involve full dismantling, with any part replaced or restored, and restores the full or nearly full service life. At power plants, the Russian operating rules also require an overspeed test, a valve tightness check and a stop valve closing time check after a major overhaul.
What should be prepared for a steam turbine overhaul?
The model and serial number, running hours and date of the last overhaul, the manufacturer’s manual, clearance records and test reports from the previous overhaul, vibration and bearing temperature trends, oil analysis results and a list of spare parts in stock. Our engineers use this data to estimate the scope of work and select parts in advance, so that nobody has to wait for them once the turbine is opened.
Engineering team
Rotating equipment service