What is a combined-cycle plant

A combined-cycle plant is a gas turbine, a heat recovery steam generator and a steam turbine working in one scheme. The heat of the gas turbine exhaust raises steam for the steam turbine, so the same fuel yields 40–50 % more electricity than in simple cycle; the overall electrical efficiency reaches 55–60 %.

Key facts

  • Components: gas turbine, heat recovery steam generator and steam turbine.
  • Electrical efficiency is 55–60 % against 32–40 % in simple cycle.
  • About one and a half times more electricity from the same fuel.
  • Configurations: two-on-one, one-on-one and single-shaft.
  • Starts more slowly than a simple-cycle gas turbine because the steam part must warm up.

How it is built

The gas turbine burns fuel and drives its generator; its exhaust at 450–600 °C passes through the heat recovery steam generator, where it gives heat to water and steam. The steam expands in a steam turbine with its own generator or on a common shaft with the gas turbine (single-shaft scheme). The exhaust steam is condensed and the condensate returns to the boiler. The HRSG may have one, two or three pressure levels and supplementary firing to increase steam output.

Why the efficiency is higher

In simple cycle the exhaust heat is lost and the electrical efficiency is 32–40 %. In combined cycle this heat is additionally converted into work in the steam cycle, and the overall electrical efficiency reaches 55–60 %. For the same fuel consumption the plant produces about one and a half times more electricity, and the specific CO2 and NOx emissions per kilowatt-hour fall accordingly.

Configurations

Two gas turbines with two HRSGs on one steam turbine; one gas turbine and one steam turbine; single-shaft — gas turbine, steam turbine and a common generator on one shaft. A combined-cycle CHP plant supplies heat from the steam turbine extraction. Small combined-cycle plants are built around gas turbines of a few megawatts with 2.5–80 MW turbine generator sets.

Where it is used

Large and medium power stations, CHP plants, captive power plants of industrial sites needing both steam and electricity. Equipment on this site: 42–308 MW gas turbines, 2.5–80 MW condensing and back-pressure turbine generator sets, control systems for turbines and boilers.

Operating features

The steam part limits start-up speed: the HRSG and steam lines are warmed up to a schedule, so a combined-cycle start takes longer than a simple-cycle gas turbine start. Maintenance combines gas turbine service by operating hours, steam turbine and boiler overhauls and tuning of the common control system.

Questions and answers

How does a combined-cycle plant differ from a gas turbine?

A gas turbine in simple cycle releases its 450–600 °C exhaust to the atmosphere. In a combined-cycle plant this heat raises steam for a steam turbine, so electrical efficiency rises from 32–40 % to 55–60 %. The price is a heat recovery steam generator, a steam turbine, a cooling system and a longer start.

What is a heat recovery steam generator?

A heat exchanger downstream of the gas turbine in which the exhaust gases heat water and produce steam for a steam turbine or process use. It may have one, two or three pressure levels, and supplementary firing increases steam output.

Which steam turbines are used in small combined-cycle plants?

Condensing or back-pressure turbine generator sets of 2.5–80 MW, with the flow path designed for the steam conditions of the heat recovery boiler. Ratings are on the steam turbines for power generation page. The turbine is matched to the steam pressure and temperature the heat recovery boiler delivers at the design point.