What is a turbine generator set

A turbogenerator is a synchronous generator driven by a steam or gas turbine; a turbine generator set is the turbine, a gearbox (at high turbine speed), the generator and the lube oil, excitation and control systems on a common baseplate. It produces electricity for the grid or the plant’s own needs; the steam sets on this site are rated 2.5–80 MW.

Key facts

  • A turbine generator is a synchronous generator driven by a steam or gas turbine.
  • The set: turbine, gearbox, generator, lube oil, excitation and control.
  • Delivered as a package on a single baseplate.
  • Runs in parallel with the grid or in island mode holding 50 Hz.
  • Steam units on this site: 2.5–80 MW.

What the set consists of

A steam turbine at 3,000–11,000 rpm; a gearbox reducing the speed to the generator’s 3,000 or 1,500 rpm; an air- or hydrogen-cooled synchronous generator; the excitation system with an automatic voltage regulator; a lube oil system common to the turbine, gearbox and generator; an automatic control system with protection, synchronisation and load control. The set is delivered as a package on a single baseplate.

Operating modes

In parallel with the grid the generator is synchronised and delivers the set output; in island mode the turbine governor holds 50 Hz and the excitation regulator holds the voltage. Condensing sets give the maximum electricity, back-pressure sets give electricity and process steam; controlled extraction lets the ratio be changed.

Where it is used

Captive generation of industrial sites on boiler or heat-recovery steam, mill CHP plants, the steam part of combined-cycle plants, recovery of process heat. The turbine flow path is designed individually for the customer’s steam parameters, which gives high internal efficiency over a wide load range.

Maintenance

Installation supervision and commissioning, shaft-line vibration diagnostics, alignment of turbine, gearbox and generator, flow-path overhauls, winding insulation and excitation checks, tuning of governors and protection. The team’s experience: steam turbines for mill CHP plants and electrical equipment for ships.

Questions and answers

Why does a turbine generator set need a gearbox?

A small steam turbine is more efficient at high speed — 3,000–11,000 rpm — while a generator for a 50 Hz grid runs at 3,000 or 1,500 rpm. The gearbox matches the speeds and lets the turbine flow path be designed for the steam conditions without compromise.

Can a turbine generator run without the grid?

Yes, in island mode: the turbine governor holds 50 Hz and the excitation regulator holds the voltage. This mode matters for sites without a reliable grid and during system faults; transfers between modes are set up during commissioning.

Which turbine generator sets does Energy Management supply?

Steam sets of 2.5–80 MW in condensing and back-pressure versions, with and without controlled extraction, inlet steam up to 540 °C and 14 MPa abs. Ratings are on the steam turbines for power generation page.

Related terms

Updated: 2026-09-23

CallSend a request