What is a back-pressure turbine
A back-pressure turbine is a steam turbine that exhausts steam above atmospheric pressure, 0.25–4.0 MPa (up to 6.5 MPa for drive machines), into a process network or district heating. The steam does work in the turbine and is then used by consumers, so the overall fuel utilisation reaches 80–90 %. There is no condenser; the turbine output depends on the consumers’ steam demand.
Key facts
- Exhausts steam at 0.25–4.0 MPa to consumers, up to 6.5 MPa for drive machines.
- No condenser, so the plant is simpler and cheaper.
- Overall fuel utilisation reaches 80–90 %.
- Output depends on the consumers’ steam demand.
- Turns into work the pressure drop that would otherwise be throttled.
How it works
The boiler raises high-pressure steam, the turbine expands it to the pressure the consumers need and delivers work to a generator or a driven machine. The turbine replaces a pressure-reducing and desuperheating station: the pressure drop that would otherwise be throttled away is turned into electricity or drive power. The governor holds the exhaust pressure or the speed; surplus steam is dumped through a reducing station.
Where it is used
Pulp and paper mills, refining and petrochemicals, sugar and chemical plants, works CHP plants — wherever there is a constant demand for medium-pressure steam. The small RLA, RLVA and RLH turbines with back pressure up to 12–22 bar drive pumps and fans on steam that then goes to the process.
Advantages and limits
No condenser, no cooling system and no condensation losses, so the plant is simpler, cheaper and more fuel-efficient. The limit is that electricity output is tied to steam consumption: in summer, when little steam is needed, the output falls. That is why CHP plants combine back-pressure turbines with condensing or extraction turbines.
Ratings on this site
Turbine generator sets of 2.5–80 MW with exhaust at 0.25–4.0 MPa(a); drive turbines of 8 kW – 50 MW with back pressure up to 6.5 MPa, with and without extraction; small single-stage turbines up to 1,865 kW.
Questions and answers
Why is a back-pressure turbine more economical than a condensing one?
The heat of the exhaust steam is not lost in a condenser but goes to consumers — to the process or to heating. Overall fuel utilisation therefore reaches 80–90 %, although each tonne of steam gives less electricity than in a condensing turbine.
What happens in summer when less steam is needed?
Turbine output falls together with the consumers’ steam demand. That is why CHP plants combine back-pressure turbines with condensing or extraction turbines, and surplus steam is dumped through a reducing station when necessary.
Where does a back-pressure turbine pay off?
At plants with a constant demand for medium-pressure steam: pulp and paper mills, refineries, chemical and sugar plants, works CHP plants. Industry solutions are on the pulp and paper industry page. The economics are assessed from the annual steam demand profile.
Related terms
Updated: 2026-09-23