Equipment for refining and petrochemicals
Compressors for hydrocarbons, syngas, ethylene, propylene and hydrogen: centrifugal up to 15 MPa, API 618 reciprocating up to 50 MPa, diaphragm up to 45 MPa for hydrogen and aggressive gases, screw compressors to API 619. API 611/612 mechanical drive steam turbines and small RLA, RLVA and RLH turbines for pump and fan drives. Service and spare parts for Siemens Energy and Dresser-Rand equipment.

Industry task → our equipment and services
| Industry task | Equipment | Services |
|---|---|---|
| Compression of hydrocarbons, syngas, ethylene and propylene | Centrifugal compressors up to 15 MPa | Compressor service and repair |
| Hydrogen and aggressive gases | API 618 reciprocating compressors up to 50 MPa, diaphragm compressors up to 45 MPa | Dry gas seals |
| Steam drive for compressors | API 611/612 mechanical drive steam turbines | Steam turbine service |
| Pump and fan drives | Small RLA, RLVA and RLH turbines | Installation supervision and commissioning |
| Spare parts for the installed fleet | Siemens Energy spare parts | Dresser-Rand spare parts |
| Compressor protection against surge | Compressor control systems | Anti-surge control |
Which compressor a refinery or petrochemical unit needs
Compressors for refineries and petrochemical plants are selected by the gas, the flow and the pressure ratio. The industry has typical choices for the main services; the machine for a specific unit is defined by the enquiry data sheet.
| Unit and service | Gas | Usual machine type |
|---|---|---|
| Hydrotreating and hydrocracking — make-up | hydrogen | reciprocating, API 618 |
| Hydrotreating and hydrocracking — recycle | hydrogen-rich gas | centrifugal (API 617) or reciprocating |
| Fluid catalytic cracking | wet gas | centrifugal, API 617, often driven by a steam turbine |
| Steam cracking | cracked gas; propylene and ethylene in refrigeration cycles | multi-section centrifugal, API 617, driven by steam turbines |
| Ammonia and methanol production | syngas | centrifugal, API 617, driven by a steam turbine |
| Flare gas recovery | hydrocarbon gas of variable composition | screw (API 619) or liquid-ring |
We supply API 617 centrifugal compressor trains up to 15 MPa, 300,000 Nm³/h and 30 MW driven by a steam turbine or an electric motor, API 618 reciprocating compressors up to 50 MPa, API 619 oil-free and oil-flooded screw compressors up to 1.3 MPa, and diaphragm compressors up to 45 MPa. Machines for hydrogen-rich gases are covered on the Hydrogen compressors page.
Mechanical drive steam turbines for refineries: API 611 or API 612
At a refinery, a mechanical drive turbine is usually built into the plant steam system: it uses the steam pressure drop and exhausts steam into a lower-pressure plant header. This is why back-pressure turbines and extraction turbines are widely used. The standard depends on how critical the service is.
- API 611 (6th edition, 2022): general-purpose turbines for equipment that is usually spared or in non-critical service, typically with steam up to 48 bar g and 400 °C and speed up to 6,000 rpm. Typical duties are pumps and fans.
- API 612 (8th edition, 2020): special-purpose turbines for uninterrupted, continuous operation in critical service, usually with no installed spare; the standard does not limit steam conditions, power or speed. Drives of wet gas, cracked gas and syngas compressors fall into this category.
The mechanical drive turbines we supply are built to API 611/612 for 8 kW – 50 MW, 1,000–15,000 rpm and steam up to 540 °C and 14 MPa(a); back-pressure and extraction designs are available, and a turbine can be supplied as a package on a single baseplate.
What makes it different
- Gases
A compressor type for every gas
Centrifugal for high flows, diaphragm for hydrogen and aggressive media with no oil contact, screw compressors to API 619 for process gases.
- Steam
The steam turbine as a driver
API 611/612 mechanical drive turbines use the plant’s steam to drive compressors and pumps; the small RLA, RLVA and RLH turbines drive pumps and fans.
- Spare parts
Parts for the Siemens Energy and Dresser-Rand fleet
Selection by the machine data sheet, supply and replacement during repairs, dry gas seals — for the installed fleet of compressors and turbines.
Service and spare parts for refining and petrochemicals
We service centrifugal compressor trains and steam turbines rated from 750 kW to 80 MW and supply spare parts for Siemens Energy and Dresser-Rand machines, including those operating at petrochemical plants.
- Refinery equipment reliability. On 4 June 2024, at the LUKOIL PJSC conference on the reliability of refinery equipment, the company spoke about service and spare parts supply for turbines, compressors, high-voltage equipment and automation systems. In March 2024 it gave a presentation at the Downstream 2024 conference.
- Siemens STC-SV turbocompressors in gas condensate processing. In July 2023 our specialists carried out a scheduled Level 1 inspection of two such machines at the facilities of the Gazprom Pererabotka condensate treatment plant, as confirmed by a letter from GSP Remont LLC.
- Spare parts. For STC and Datum compressors and SST, RLA and RLVA steam turbines we supply seals, including dry gas seals, bearings, flow path components and spares for vibration monitoring systems (all spare parts). We confirm the origin of parts by catalogue numbers, markings and accompanying documents.
- Preparing for a turnaround. Unspared machines can usually only be overhauled while the unit is shut down, so the scope of work and the parts are defined in advance, based on a diagnostic survey that assesses the condition of the equipment and forecasts upcoming maintenance.
Customers for whom the company’s specialists have supplied and commissioned equipment and systems include SIBUR and LUKOIL.
Questions and answers
Which compressors are suitable for hydrogen?
It depends on flow and pressure. API 618 reciprocating compressors, up to 50 MPa and 115,000 m³/h, are the main type for make-up hydrogen in hydrotreating and hydrocracking units. API 617 centrifugal compressors handle hydrogen-rich mixtures at high flow and pressures up to 15 MPa. <a class="term-link" href="../glossary/diaphragm-compressor/index.html" title="What is a diaphragm compressor">Diaphragm compressors</a>, up to 45 MPa at up to 1,000 Nm³/h, are used when the gas must not come into contact with oil.
How does a mechanical drive turbine differ from a generator drive?
A <a class="term-link" href="../glossary/mechanical-drive/index.html" title="What is mechanical drive by a turbine">mechanical drive</a> turbine to API 611/612 turns a compressor or pump, directly or through a gearbox, and can usually vary its speed to suit the driven machine; a generator drive turbine turns a generator at constant speed and produces electricity.
Do you supply spare parts for Siemens Energy and Dresser-Rand equipment?
Yes: parts are selected by the machine data sheet and supplied for scheduled and emergency repairs.
Which standard should a steam turbine driving a refinery compressor meet: API 611 or API 612?
If the compressor runs continuously in critical service with no standby unit, the turbine is usually ordered to API 612, the standard for special-purpose turbines. API 611 covers spared or non-critical equipment, typically with steam up to 48 bar g and 400 °C. The mechanical drive turbines we supply are built to API 611/612; the requirements are recorded in the enquiry data sheet.