Company ·

Mobile test laboratory: two resonant test systems for GIS testing up to 750 kV

Energy Management’s own high-voltage test laboratory includes two mobile AC resonant test systems, WRV 3.6/680 M and WRV 1.5/680 G, for testing gas-insulated switchgear (GIS) at test voltages up to 750 kV. The laboratory is registered with Rostechnadzor and is entitled to perform acceptance tests and measurements of electrical equipment rated up to 750 kV.

Mobile resonant test system on site
Mobile resonant test system on site (illustration)

A high-voltage test laboratory is set up to ensure the sound operation of a company’s electrical installations: scheduled measurements and checks confirm that their electrical characteristics meet the applicable standards.

Energy Management LLC has its own test laboratory with two mobile AC resonant test systems: WRV 3.6/680 M and WRV 1.5/680 G. The systems are designed for testing gas-insulated switchgear (GIS) at test voltages up to 750 kV.

Registration with Rostechnadzor

The company’s electrical test laboratory with a portable set of instruments is registered with the Interregional Technological Directorate of Rostechnadzor: certificate No. 9834 of 20 December 2024. The certificate entitles the laboratory to perform acceptance tests and measurements of electrical equipment and installations rated up to 750 kV. The permitted tests include GIS, metal-clad and outdoor switchgear, SF6, air-blast, oil and vacuum circuit breakers, load break switches, current and voltage instrument transformers, disconnectors, insulators, bushings, busbars and bus ducts, as well as insulation resistance measurement of apparatus and secondary circuits up to 1 kV. The laboratory’s test systems have been certified for testing GIS and other high-voltage equipment.

Laboratory services

The laboratory tests and measures high-voltage equipment from 110 to 750 kV: GIS, SF6 circuit breakers, disconnectors and earthing switches, current and voltage transformers. The services include insulation strength checks, high-voltage testing, partial discharge measurement, insulation resistance measurement and circuit breaker timing tests. Tests are carried out in compliance with the state standards on measurements, occupational safety requirements and metrological assurance.

Under a contract signed in September 2025 the company’s specialists carried out high-voltage tests with partial discharge measurement of the 400 kV GIS at the Akkuyu NPP site in Turkey. Later they carried out high-voltage tests with partial discharge measurement of the 400 kV GIS and 400 kV SF6 bus ducts as part of the energisation of the right-hand section of the 400 kV GIS. Akkuyu Nuclear JSC recognised this work in letters of appreciation dated 4 November and 22 December 2025.

Related

Adjacent news

All news

CallSend a request